Area Measurement
For area/surface measurements, press button 12 until the in-
dicator for area measurement appears on the display.
Afterwards, measure the length and the width, one after an-
other, in the same manner as a length measurement. The laser
beam remains switched on between both measurements.
Upon completion of the second measure-
ment, the surface is automatically calcu-
lated and displayed in the result line c.
The individual measured values are dis-
played in the measured-value lines a.
Volume Measurement
For volume measurements, press button 12 until the indica-
tor for volume measurement appears on the display.
Afterwards, measure the length, width and the height, one af-
ter another, in the same manner as for a length measurement.
The laser beam remains switched on between all three meas-
urements.
Upon completion of the third measure-
ment, the volume is automatically calcu-
lated and displayed in the result line c.
The individual measured values are dis-
played in the measured-value lines a.
Values above 999999 m
3
cannot be indi-
cated; “ERROR appears on the display. Divide the volume to
be measured into individual measurements; their values can
then be calculated separately and then summarized.
Continuous Measurement (Tracking) / Minimum/Maxi-
mum Measurement (see figure B)
For continuous measurements, the measuring tool can be
moved relative to the target, whereby the measuring value is
updated approx. every 0.5 seconds. In this manner, as an ex-
ample, you can move a certain distance away from a wall,
while the actual distance can always be read.
For continuous measurements, press function mode button 4
until the indicator for continuous measurement appears on
the display. To start the continuous measurement, press the
measuring button 2.
The minimum measurement is used to determine the shortest
distance from a fixed reference point. It is used, as an exam-
ple, for determining plumb lines or horizontal partitions.
The maximum measurement is used to determine the greatest
distance from a fixed reference point. It is used, as an exam-
ple, for determining diagonals.
The current measuring value is displayed
in the result line c. The maximal (“max”)
and the minimal (“min”) measuring value
are displayed in the measured-value lines
a. It is always overwritten, when the cur-
rent length measurement value is less
than the present minimal or larger than
the present maximal value.
The previous minimal and maximal values are deleted by
pressing the button for clearing the internal memory 8.
Pressing the measuring button 2 ends the continuous meas-
urement. The last measured value is displayed in the result
line c. Pressing the measuring button 2 again restarts a con-
tinuous measuring run.
Continuous measurement automatically switches off after
5 min. The last measured value remains indicated in the result
line c.
Indirect Distance Measurement
The indirect distance measurement is used to measure dis-
tances that cannot be measured directly because an obstacle
would obstruct the laser beam or no target surface is available
as a reflector. This measuring procedure can only be used in
vertical direction. Any deviation in horizontal direction leads
to measuring errors.
The laser beam remains switched on between the individual
measurements.
For indirect length measurements, three measuring modes
are available. Each measuring mode can be used for deter-
mining different distances.
a) Indirect height measurement (see figure C)
Press the function-mode button 4 until the indication for indi-
rect height measurement appears on the display.
Pay attention that the measuring tool is positioned at the
same height as the bottom measuring point. Now, tilt the
measuring tool around the reference plane and measure dis-
tance “1” as for a length measurement.
Upon completion of the measurement,
the result for the sought distance “X” is
displayed in the result line c. The measur-
ing values for the distance
“1” and the an-
gle “α are displayed in the measured-
value lines a.
b) Double indirect height measurement (see figure D)
Press the function-mode button 4 until the indication for dou-
ble indirect height measurement appears on the display.
Measure distances “1” and “2” in this sequence as for a
length measurement.
Upon completion of the measurement,
the result for the sought distance “X” is
displayed in the result line c. The measur-
ing values for the distances “1”, “2” and
the angle “α are displayed in the meas-
ured-value lines a.
Pay attention that the reference plane of the measurement
(e.g. the rear edge of the measuring tool) remains exactly at
the same location for all individual measurements within a
measuring sequence.
c) Indirect length measurement (see figure E)
Press the function-mode button 4 until the indication for indi-
rect length measurement appears on the display.
Pay attention that the measuring tool is positioned at the
same height as the sought measuring point. Now, tilt the
measuring tool around the reference plane and measure dis-
tance “1” as for a length measurement.
1
1
2
1