English | 9
Bosch Power Tools 1 609 92A 4GN | (28.6.18)
Indirect Distance Measurement and Vial
Measuring range –60° – +60° –60° – +60°
Gradient measurement
Measuring range 0°–360° (4x90°)
C)
0°–360° (4x90°)
C)
Measuring accuracy (typical) 0.2°
D)F)
±0.2°
D)F)
Lowest indication unit 0.1° 0.1°
General
Operating temperature –10 °C...+50 °C
E)
–10 °C...+50 °C
E)
Storage temperature –20 °C...+50 °C –20 °C...+50 °C
Allowable charging temperature range
+5 °C...+40 °C +5 °C...+40 °C
Relative air humidity, max.
90 % 90 %
Laser class
22
Laser type
635 nm, <1 mW 635 nm, <1 mW
Laser beam diameter (at 25 °C) approx.
–at 10m distance
–at 80m distance
6mm
F)
48 mm
F)
6mm
F)
48 mm
F)
Setting accuracy of the laser to the housing, approx.
–Vertical
– Horizontal
±2 mm/m
G)
±10mm/m
G)
±2mm/m
G)
±10 mm/m
G)
Automatic switch-off after approx.
–Laser
– Measuring tool (without measurement)
20 s
5min
20 s
5min
Weight according to EPTA-Procedure 01:2014
0.14 kg 0.14 kg
Dimensions
51 x 111 x 30 mm 51 x 111 x 30 mm
Degree of protection
IP 54 (dust and splash water
protected)
IP 54 (dust and splash water
protected)
Measuring rail
Article number – 3 601 K79 000
Dimensions
– 58 x 610 x 30 mm
Battery
Li-Ion Li-Ion
Rated voltage
3.7 V 3.7 V
Capacity
1.25 Ah 1.25 Ah
Number of battery cells
11
Single measurements per battery charge, approx.
25000
H)
25000
H)
Digital Laser Measure GLM 80 GLM 80+R60
A) For measurements from the front measuring tool edge, 100% reflectivity of the target (e.g. a white wall), weak backlighting and 25 °C operating
temperature. In addition, a deviation influence of ±0.05 mm/m must be taken into account.
B) For measurements from the rear measuring-tool edge, 10 – 100 % reflectance of the target, strong backlight and – 10 °C to +50 °C operating tem-
perature. Additionally, a deviation influence of ±0.29 mm/m must be taken into account.
C) For measurements with the rear side of the unit as reference, the max. measuring range is ±60°
D) After calibration in accordance with figure H. Additional pitch error of ±0.01 °/degrees up to 45 °.
E) In the continuous measurement function, the maximum operating temperature is +40 °C.
F) The width of the laser line depends on the surface characteristics and on the ambient conditions.
G) at 25 °C
H) For a new and charged battery without display illumination and tone signal.
The measuring tool can be clearly identified with the serial number 18 on the type plate.
OBJ_BUCH-3509-001.book Page 9 Thursday, June 28, 2018 9:49 AM