EasyManua.ls Logo

Bosch GLM Professional 80 - Page 9

Bosch GLM Professional 80
73 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English | 9
Bosch Power Tools 1 609 92A 4GN | (28.6.18)
Indirect Distance Measurement and Vial
Measuring range 60° +60° 60° +60°
Gradient measurement
Measuring range 0°–36 (4x9)
C)
0°–36 (4x9)
C)
Measuring accuracy (typical) 0.2°
D)F)
±0.
D)F)
Lowest indication unit 0.1° 0.1°
General
Operating temperature –10 °C...+50 °C
E)
–10 °C...+50 °C
E)
Storage temperature –20 °C...+50 °C –20 °C...+50 °C
Allowable charging temperature range
+5 °C...+40 °C +5 °C...+40 °C
Relative air humidity, max.
90 % 90 %
Laser class
22
Laser type
635 nm, <1 mW 635 nm, <1 mW
Laser beam diameter (at 25 °C) approx.
–at 10m distance
–at 80m distance
6mm
F)
48 mm
F)
6mm
F)
48 mm
F)
Setting accuracy of the laser to the housing, approx.
–Vertical
Horizontal
±2 mm/m
G)
±10mm/m
G)
±2mm/m
G)
±10 mm/m
G)
Automatic switch-off after approx.
–Laser
Measuring tool (without measurement)
20 s
5min
20 s
5min
Weight according to EPTA-Procedure 01:2014
0.14 kg 0.14 kg
Dimensions
51 x 111 x 30 mm 51 x 111 x 30 mm
Degree of protection
IP 54 (dust and splash water
protected)
IP 54 (dust and splash water
protected)
Measuring rail
Article number 3 601 K79 000
Dimensions
58 x 610 x 30 mm
Battery
Li-Ion Li-Ion
Rated voltage
3.7 V 3.7 V
Capacity
1.25 Ah 1.25 Ah
Number of battery cells
11
Single measurements per battery charge, approx.
25000
H)
25000
H)
Digital Laser Measure GLM 80 GLM 80+R60
A) For measurements from the front measuring tool edge, 100% reflectivity of the target (e.g. a white wall), weak backlighting and 25 °C operating
temperature. In addition, a deviation influence of ±0.05 mm/m must be taken into account.
B) For measurements from the rear measuring-tool edge, 10 100 % reflectance of the target, strong backlight and 10 °C to +50 °C operating tem-
perature. Additionally, a deviation influence of ±0.29 mm/m must be taken into account.
C) For measurements with the rear side of the unit as reference, the max. measuring range is ±60°
D) After calibration in accordance with figure H. Additional pitch error of ±0.01 °/degrees up to 45 °.
E) In the continuous measurement function, the maximum operating temperature is +40 °C.
F) The width of the laser line depends on the surface characteristics and on the ambient conditions.
G) at 25 °C
H) For a new and charged battery without display illumination and tone signal.
The measuring tool can be clearly identified with the serial number 18 on the type plate.
OBJ_BUCH-3509-001.book Page 9 Thursday, June 28, 2018 9:49 AM

Related product manuals