Bosch Greenstar combi 151 p - Overview of the Service Functions; Service-Level 1 (Press and Hold the Service Button until It Lights Up); Second Service Level (at First Service Level, Service Button Lights Up, Press ECO Button and Key Pad Lock Button Simultaneously until 8.A Appears); Description of the Service Functions

Bosch Greenstar combi 151 p
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40 | Heatronic boiler control settings
Greenstar combi 100 p / 151 p6720872361 (2017/04)
Restoring factory settings
In order to reset all values for the service levels 1 and 2 to the factory
setting:
Press and hold the service button until it lights up.
The display shows a code such as 1.A (first service level). Press the
button and key pad lock button simultaneously until the code 8.A
appears (second service level).
On the second service level, select the service function 8.E and value
00. The appliance restarts with the default settings.
10.2 Overview of the service functions
10.2.1 Service-level 1 (Press and hold the service button until
it lights up)
Table 22 Service functions, 1nd level
10.2.2 Second service level (at first service level, service button
lights up, press ECO button and key pad lock button
simultaneously until 8.A appears)
Table 23 Service functions, 2nd level
10.3 Description of the service functions
10.3.1 First service level
Service function 1.A: Maximum space heating output
Some gas supply companies offer a performance-dependent basic
price.
The output can be limited in percent between the minimum and
maximum nominal output to suit the specific heat demand.
Even if the heating output has been limited, the maximum nominal
output is still available for DHW generation.
Select service function 1.A.
Select heat output in MBH (kW) and determine associated setting in
percent (%).
Enter the setting ( Chapter 10.1).
Save the setting ( Chapter 10.1).
Record the set heat output in the commissioning log ( page 60).
Exit the service functions.
The display returns to the supply temperature.
The factory setting is the maximum nominal output: U0 (100 %).
Service function 1.b: Maximum DHW output
The hot water output can be adjusted between the minimum and
maximum DHW outputs to suit the heat transfer capacity of the DHW
tank coil.
Select service function 1.b.
Select the DHW output in MBH (kW) and determine the associated
setting in percent (%).
Enter the setting ( 10.1).
Save the setting ( 10.1).
Service function
Display Page
1.A Maximum space heating output 40
1.b Maximum DHW output 40
1.E Pump mode for space heating operation 41
1.F
a
a. Service functions 1.F and 5.E are not used.
- 41
2.C Bleeding function 41
2.d Thermal disinfection 41
2.F Operating mode 41
3.A Automatic anti-cycle function 41
3.b Set anti-cycle time 42
3.C Switching differential (hysteresis) 42
3.d Minimum output (heating and DHW) 42
3.E Cycle time, keeping DHW hot 42
3.F Constant DHW period 42
4.b Maximum heat exchanger temperature 42
4.d Audible fault warning tone 42
4.E Appliance type 42
4.F Condensate trap filling sequence 42
5.A Reset inspection interval 43
5.b Fan post purge time 43
5.E
a.
- 43
5.F Set inspection interval 43
6.A Display the latest fault code 43
6.b Room temperature control, current voltage,
terminal 2
43
6.C Supply temperature required by outdoor reset
control
43
6.d Current DHW turbine flow rate 43
7.A Indicator lamp for burner operation / faults 43
7.b 3-way valve in center position 43
7.d Connecting an external supply or low-loss header
temperature sensor
43
7.E Building drying function 43
0.A Do not use this setting! 43
0.d Altitude adjustment 44
0.E Metric or US customary units 44
Service function
Display Page
8.A Software version 44
8.b Code plug number 44
8.C GFA Gas burner control status
a
a. GFA: Gas burner control unit
44
8.d GFA fault 44
8.E Restore boiler to factory settings 44
8.F Permanent ignition 44
9.A Constant mode 44
9.b Current fan speed 44
9.C Current boiler output 44
9.d Set fan start speed 44
9.E Turbine signal delay 45
9.F Heating zone pump post purge 45
A.b Display DHW temperature 45
A.C Display DHW tank temperature 45
b.F Solar DHW backup heating delay 45
C.d Display current heat demand 45

Table of Contents

Other manuals for Bosch Greenstar combi 151 p

Related product manuals