6 720 816 815 (2018/08)Greentherm T9800 SE 160/199 | SEC 199
Installation instructions | 15
Fig. 8 Leveling wall mounting bracket
Fig. 9 Mounting the heater
4.6 Venting
CAUTION: Personal injury and property
damage.
▶ Appliance must be installed vertically.
DANGER:
▶ Do not reduce the exhaust or
combustion air vent pipe sizes.
▶ Do not common vent with any other
vented appliance or stove.
▶ Do not use Type-B vent as the actual
exhaust vent system for the appliance.
DANGER: Flue gas poisoning!
▶ Failure to vent the exhaust gases to the
outside (see table 5 for proper material)
may result in dangerous flue gases filling
the structure in which it is installed.
NOTICE:
▶ Installations resulting in negative
pressure/back draft require sealed
combustion (twin pipe / concentric).
Damage caused from back draft, ie.
freezing, is not covered by warranty.
NOTICE: Appliance malfunction!
▶ Protect the exhaust and inlet from
leaves and debris by installing a screen
on the end of the termination. ¼ " mesh
minimum opening is recommended on
screen.
▶ Do not install the water heater in areas
where dust and chemicals like hair
sprays, spray detergents, chlorine, may
accumulate.