EasyManua.ls Logo

Bosch GRL4000-80CH - Control and Status Overviews

Bosch GRL4000-80CH
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-34-
Overview of status indicators
Measuring tool Function
Green Red
Horizontal position: X- or Y-axis levelling process.
Vertical position: X-axis levelling process.
Sleep mode activated.
Horizontal position: Both axes are levelled.
Vertical position: X-axis is levelled.
automatic shut-down due to error message (e.g. empty rechargeable/non-rechargeable battery,
operating temperature exceeded).
Centre line mode started (see operating instructions for the laser receiver).
Position of the measuring tool changed without switching on/off.
Self-levelling not possible, end of the self-levelling range.
Shock-warning function actuated.
Measuring tool is being calibrated.
Horizontal position: At least one axis is tilted or is in manual operating mode.
Vertical position: X-axis is tilted or in manual operating mode.
●lighting up continuously
flashing
Remote control
X
Remote control
Y
Function
Green Red Green Red
X-axis levelling process (horizontal and vertical positions).
Y-axis levelling process (horizontal position).
Remote control is connected via Bluetooth®.
(Both of the status indicators flash alternately.)
Remote control successfully connected via Bluetooth®.
X-axis is levelled in (horizontal and vertical positions).
Y-axis is levelled in (horizontal position).
X-axis is tilted or in manual operating mode (horizontal and vertical
positions).
Y-axis is tilted or in manual operating mode (horizontal position).
Unsuccessful connection to the measuring tool via Bluetooth®.
●lighting up continuously