30/68 Installation
Bosch Rexroth Mellansel AB, Installation and maintenance manual , Hägglunds CB, RE 15302-WA/05.2019
Fig. 22: Standard articulated connection TC A
Slot
Fr
DD00100584
Fig. 23: Electrical isolated articulated connection TC A
Pos Description Pcs
1 Linkage part 1
2 Fastening support 1
3 Bolt 2
4 Supporting disc 12
5 Circlip 4
6 Spherical plain bearing 2
7 Split pin 2
8 Washer (electrical isolated) 4
9 Bushing (electrical isolated) 4
10 Washer (electrical isolated) 4
Standard and electrical isolated articulated connection
1. The bearing (6) shall be mounted by using a mounting sleeve or tube applied on
the bearing outer ring.
2. The bearing shall be mounted with the slot in the outer ring perpendicular
towards the load direction. See Fig. 22 (also valid for Fig. 23)
3. Lock the bearings with the circlips (5)
4. Assemble the rest of the components according to Fig. 22 and Fig. 23
DD00100404