Note: Installations employing a Receptacle
7KHDFFHVVRU\FRUGNLW0RGHO60=3&8&GHVLJQHGIRUFRQQHFWLRQWR
a receptacle is not provided, but can be ordered through Customer Service
E\FDOOLQJ0DNHVXUHWKHKRXVHKROGUHFHSWDFOHPHHWVWKH
electrical supply requirements as well as national and local codes. If you
choose to permanently connect to hardwiring, follow the next steps.
Turn off any electricity to installation area.
Remove screws and cover from junction box (A) and set aside for later use .
Remove outer casing and insulationRIWKHKDUGZLULQJSRZHUFRUGDV
shown.
8
Dishwasher Electrical Rating
Volts Hertz Amperes Watts
120 60 15
1,450
(max)
12
Grounding Instructions
The dishwasher must be properly grounded before operating. This appli
ance must be connected to a grounded metal permanent wiring system or
an equipment grounding conductor must be run with the circuit conductors
and connected to the equipment grounding terminal or lead on the dish
ZDVKHU0DNHVXUHWKDWWKHGLVKZDVKHULVFRQQHFWHGWRDVXLWDEOHJURXQG
in compliance with all local codes or, in the absence of a local code, with
the NATIONAL ELECTRICAL CODE in the United States or the CANA
',$1(/(&75,& &2'( &ODWHVW HGLWLRQ LQ &DQDGD DVZHOO DV DQ\
SURYLQFLDOVWDWHRUPXQLFLSDORUORFDOFRGHVWKDWDSSO\
11