ICP-CC408 | Installation Guide | 24.0 Programming Sheets EN | 101
Bosch Security Systems, Inc. | 12/08 | F01U089463-02
Zone Pulse Count Settings
Program the pulse count settings for each zone from
0 to 15.
Zone Pulse Count Time
Zone pulse count time is the time frame or period
over which the number of pulses must register.
20 ms Loop Response 150 ms Loop Response
Option Time (sec) Option Time (sec)
0 0.5 8 20
1 1 9 30
2 2 10 40
3 3 11 50
4 4 12 60
5 5 13 90
6 10 14 120
7 15 15 200
Zone Options 1
Option Description
1 Lockout siren/lockout dialer
2 Delay alarm reporting
4 Silent alarm
8 Sensor watch
Zone Options 2
Option Description
1 Isolated in STAY Mode 1
2 Zone isolation allowed
4 Forced arming allowed
8 Enable Zone Restore Report
Zone Dialer Options
Option Description
0 No report required
1 Receiver 1
2 Receiver 2
4 Receiver 1 and 2
8 Receiver 2 only when Receiver 1 fails
Zone Descriptions
Use this table as a reference to indicate what each
zone is connected to.
Zone Description
1
2
3
4
5
6
7
8
Swinger Shutdown Count for Siren
Location
323 Refer to page 63
Default
3
Swinger Shutdown Count for Dialer
Location
324 Refer to page 63
Default
6
Zone Status – Bypass Reports
Location
325 to 326 Refer to page 64
Default
9 8
Location 325 Zone Bypass Report
Location 326 Zone Bypass Restore Report
Zone Status – Trouble Reports
Location
327 to 328 Refer to page 64
Default
2 3
Location 327 Zone Trouble Report
Location 328 Zone Trouble Restore Report
Zone Status – Sensor Watch Reports
Location
329 to 330 Refer to page 64
Default
4 5
Location 329 Sensor Watch Report
Location 330 Sensor Watch Restore Report
Zone Status – Alarm Restore Code
Location
331 Refer to page 65
Default
14
Zone Status Reporting Options
Location
332 Refer to page 65
0 No report required
1 Receiver 1
2 Receiver 2
4 Receiver 1 and 2
8 Receiver 2 only when Receiver 1 fails
Open/Close Reports
Location
333 to 334 Refer to page 65
Default
11 12
Location 333 Opening Report
Location 334 Closing Report
Open/Close Reporting Options
Location
335 Refer to page 65
0 No report required
1 Receiver 1
2 Receiver 2
4 Receiver 1 and 2
8 Receiver 2 only when Receiver 1 fails
Codepad Duress Report
Location
336 Refer to page 65
Default
6
Codepad Panic Report
Location
337 to 338 Refer to page 65
Default
7 15
Codepad Fire Report
Location
339 to 340 Refer to page 66
Default