ICP-CC408 | Installation Guide | 24.0 Programming Sheets EN | 102
Bosch Security Systems, Inc. | 12/08 | F01U089463-02
Codepad Medical Report
Location
341 to 342 Refer to page 66
Default
7 13
Codepad Reporting Options
Location
343 Refer to page 66
0 No report required
1 Receiver 1
2 Receiver 2
4 Receiver 1 and 2
8 Receiver 2 only when Receiver 1 fails
System Status – AUX Power Supply Fail Report
Location
344 to 345 Refer to page 66
Default
10 3
System Status – AUX Power Supply Fail Restore
Report
Location
346 to 347 Refer to page 66
Default
10 8
System Status – AC Fail Report
Location
348 to 349 Refer to page 66
Default
10 2
System Status – AC Fail Restore Report
Location
350 to 351 Refer to page 66
Default
10 7
System Status – Low Battery Report
Location
352 to 353 Refer to page 67
Default
10 1
System Status – Low Battery Restore Report
Location
354 to 355 Refer to page 67
Default
10 6
System Status – Access Denied
Location
356 to 358 Refer to page 67
Default
6 7 12
Location 356 Code retries
Location 357 Reporting code – tens digit
Location 358 Reporting code – units digit
System Status Reporting Options
Location
359 Refer to page 67
0 No report required
1 Receiver 1
2 Receiver 2
4 Receiver 1 and 2
8 Receiver 2 only when Receiver 1 fails
Test Reporting Time
Location
360 to 366 Refer to page 67
Default
0 0 0 0 7 1 0
Location 360 Hour of the day – tens digit
Location 361 Hour of the day – units digit
Location 362 Minute of the day – tens digit
Location 363 Minute of the day – units digit
Location 364 Test Report code – tens digit
Location 365 Test Report code – units digit
Location 366 Repeat interval in days
Test Reporting Dialer Options
Location
367 Refer to page 68
0 No report required
1 Receiver 1
2 Receiver 2
4 Receiver 1 and 2
8 Receiver 2 only when Receiver 1 fails
Output Configurations
Location
368 to 397 Refer to page 68
Output 1
Locations 368 to 373
Default for horn speaker
1 14 0 0 0 0
Output 2
Locations 374 to 379
Default for Fire Alarm
verification
2 7 10 2 1 5
Strobe
Locations 380 to 385
Default for strobe (reset in 8 hr)
2 0 6 4 0 8
Relay
Locations 386 to 391
Default for sirens running
1 15 1 0 0 0
Codepad
Locations 392 to 397
Default for entry/Exit Warning
and Delay Alarm
0 13 2 1 0 1
Outputs are programmed with four parameters in six
locations:
Event Type Polarity Time Base Time Multiplier
Entry Time 1
Location
398 to 399 Refer to page 76
Default
4 1
Location 398 Increments of 1 sec (0 to 15 sec)
Location 399 Increments of 16 sec (0 to 240 sec)
Entry Time 2
Location
400 to 401 Refer to page 76
Default
8 2
Location 400 Increments of 1 sec (0 to 15 sec)
Location 401 Increments of 16 sec (0 to 240 sec)
Exit Time
Location
402 to 403 Refer to page 76
Default
12 3
Location 402 Increments of 1 sec (0 to 15 sec)
Location 403 Increments of 16 sec (0 to 240 sec)
Entry Guard Time for STAY Mode
Location
404 to 405 Refer to page 76
Default
0 0
Location 404 Increments of 1 sec (0 to 15 sec)
Location 405 Increments of 16 sec (0 to 240 sec)
Delay Alarm Reporting Time
Location
406 to 407 Refer to page 76
Default
0 0
Location 406 Increments of 1 sec (0 to 15 sec)
Location 407 Increments of 16 sec (0 to 240 sec)