Easy Series (ICP-EZM2) | Installer Guide | 4.0 Programming
.
Bosch Security Systems, Inc. | 5/07 | F01U025147-01 39
Programming Item
Item
Number
Description (Range) Entry
Swinger Bypass
Count
131
1 = One alarm report allowed from point while system is on before point
is bypassed.
2 = Two alarm reports allowed from point while system is on before point
is bypassed.
3 = Three alarm reports allowed from point while system is on before
point is bypassed.
1
Auto Protection Level 132 0 = System always turns on (unoccupied) when selected.
1 = System only turns on (unoccupied) if a perimeter point is faulted
during Exit Delay. If no point is faulted, the system turns on
(occupied).
1
System On Order
Options
133 Determines the order that system-on options are announced to the user.
1 = “Stay
1
,” “Leave
2
,” “Custom
3
”
2 = “Stay,” “Custom,” “Leave”
3 = “Leave,” “Stay,” “Custom”
4 = “Leave,” “Custom,” “Stay”
5 = “Custom,” “Leave,” “Stay”
6 = “Custom,” “Stay,” “Leave”
1
“Stay” = System On Occupied
2
“Leave” = System On Unoccupied
3
“Custom”: Only announced if points are programmed as Custom
Protection points. Refer to Section 4.2.1 Point Programming Items on
page 46 to assign Custom Protection points.
1
Cross Zone Timer 134
Enter how long the system waits for at least two Cross Zone points to be
faulted before the control panel sends a Verified Alarm report to the
central station (60 to 3600 sec).
If only one Cross Zone point is faulted during this time, the control panel
sends an Unverified Alarm report to the central station.
The cross zone timer is also used as the confirmed alarm timer.
120
Restricted Alarm
Memory
136 0 = Any user can clear the alarm memory.
1 = Only the master user can clear the alarm memory.
0
Latching Point and
Enclosure Tamper
137
0 = Any user token or passcode can clear a point or enclosure tamper
condition.
1 = Only the installer passcode can clear a point or enclosure tamper
condition.
0
Latching System
Device Tamper
138
0 = Any user token or passcode can clear a tamper condition from a
system device (control center, DX2010, or wireless hub).
1 = Only the installer passcode can clear a tamper condition from a
system device.
0
Verbose System Test
Enabled
139 0 = Internal tests are conducted silently, and the control center
announces the entire test status when all tests are complete.
1 = The control center announces tests as they are performed.
1
Demo Mode 140
0 = The system only announces all telephone menu messages over the
phone.
1 = The system announces all telephone menu messages over the
phone and at all control centers connected to the system.
0
Restrict Installer
Passcode
142
0 = Master user passcode or token not needed to enable Installer
Passcode.
1 = Master user must present token or enter passcode before installer
enters Installer Passcode. Installer passcode is enabled until a user
turns the system on.
The master user can also enable installer access from the User
Phone Menu ([3] System Maintenance → [6] Expert Programming).
Refer to page 7 for more information. This setting also restricts the
availability of certain Installer Menu options.
0
Default
= Country-specific default. Select this programming item to hear the updated default value.