Easy Series (ICP-EZM2) | Installer Guide | 4.0 Programming
40 Bosch Security Systems, Inc. | 5/07 | F01U025147-01
Programming Item
Item
Number
Description (Range) Entry
Test Report Hour 143 Enter the hour that the control panel sends the test report (0 to 23).
8
Test Report Minute 144
Enter the minute that the control panel sends the test report
(0 to 59).
0
Test Report Day of
Week
145
Select the day that the control panel sends the test report.
Program Item 116 must = 2 (Weekly).
0 = Sunday 4 = Thursday
1 = Monday 5 = Friday
2 = Tuesday 6 = Saturday
3 = Wednesday
0
Test Report Day of
Month
146
Enter the day of the month that the control panel sends the test
report (1 to 28). Expert Programming Item Number 116 must = 3
(Monthly).
1
Restrict Confirmed
Alarm Memory
147 0 = User passcode can clear a confirmed alarm.
1 = Only installer passcode can clear a confirmed alarm.
0
Arming
Beeps/Graduated
Annunciation
148
0 = No arming beeps from control center and no outputs activation
during Entry Delay.
1 = No arming beeps from control center, but outputs activate during
Entry Delay.
2 = Control center sounds arming beeps, but outputs do not activate
during Exit Delay.
3 = Control center sounds arming beeps and outputs activate during
Entry Delay.
0
Wireless Jam Detect
Level
150 Configure the jam detect level of the wireless devices (0 to 15).
12
Key Fob Arming 153 0 = Do not turn system on if there are faulted points
1 = Force arm faulted points if the number of faulted points is within
the range set in Expert Programming Item Number 125 (refer to
page 38)
2 = Force arm faulted points even if the number of faulted points
exceeds the range set in Expert Programming Item Number 125
0
Two-Way Voice
Session Configuration
158 0 = Allow two-way voice session to occur at any time
1 = Restrict two-way voice session to occur only during alarm
conditions
0
Start Arming with
Faulted Points
159
0 = All faulted points must be force armed before the system can be
turned on
1 = Exit Delay starts with faulted points
1
Speak Active Faults 160 0 = Control center only speaks “Call for Service” when a fault occurs
1 = Control center speaks fault condition
0
Wireless Transmission
Attenuation
161 0 = No signal attenuation
1 = 3 dB attenuation for EN 50131 Security Grade 1
2 = 6 dB attenuation for EN 50131 Security Grade 2
3 = 9 dB attenuation for EN 50131 Security Grade 3
4 = 12 dB attenuation for EN 50131 Security Grade 4
0
Key Fob Button
Configuration
616 0 = Status request only
1 = Turn system on (occupied)
2 = Turn system on (custom protection)
3 = Turn output on or off
4 = Turn output on for 2 sec.
0
Key Fob Button
Configuration
626 0 = Status request only
1 = Turn system on (occupied)
2 = Turn system on (custom protection)
3 = Turn output on or off
4 = Turn output on for 2 sec.
0
Default
= Country-specific default. Select this programming item to hear the updated default value.