EasyManua.ls Logo

Bosch ICP-EZM2 - Page 42

Bosch ICP-EZM2
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Easy Series (ICP-EZM2) | Installer Guide | 4.0 Programming
42 Bosch Security Systems, Inc. | 5/07 | F01U025147-01
Programming Item
Item
Number
Description (Range) Entry
Call Waiting Disable 215
Enter a 3-digit string. Dial this first before dialing the premises
phone number.
* = [*][*]; # = [*][#]
Dialing a call waiting sequence on a non-call waiting phone
line prevents the system from successfully contacting the
central station.
0
Emergency Call Override
Number
216
Enter a 3-digit emergency number, such as 911. If a user
dials this number, the system waits the amount of time
entered in Expert Programming Item Number 217 before
sending reports.
000
Emergency Call Override
Number Delay
217
Enter the amount of time the system waits before sending
reports if an emergency number is dialed (0 to 60 min).
5
Auto Detect Pulse Dial 218 0 = Tone dialing only
1 = Auto Detect Pulse or Tone
0
Phone Answer Ring Count 222 Enter the number of rings before the system answers an
incoming call (1 to 255 rings).
10
Bell Test 223
This programming item applies to all Intrusion output types
and to all arming modes.
0 = No closing ring-back or bell test
1 = Enabled
If closing reports are disabled, the outputs turn on for 1
sec at the end of Exit Delay.
If closing reports are enabled, the outputs turn on for 1
sec. when the control panel receives a closing report
acknowledgement from the central station.
0
Default
= Country-specific default. Select this programming item to hear the updated default value.

Table of Contents

Other manuals for Bosch ICP-EZM2