Easy Series (ICP-EZM2) | Installer Guide | 4.0 Programming
.
Bosch Security Systems, Inc. | 5/07 | F01U025147-01 45
System Report and Restoral Routing (continued)
Programming Item Item Number Description Entry
Local Programming Success 357
3
Low Battery 358
3
Low Battery Restoral 359
3
Communication Test Manual 362
3
Phone Line Fault 363
3
Phone Line Fault Restoral 364
3
Remote Programming Failure 365
3
Remote Programming Success 366
3
Wireless Receiver Jammed 367
3
Wireless Receiver Jammed Restoral 368
3
Bus Device Tamper 369
3
Bus Device Tamper Restoral 370
3
Bus Device Trouble 373
3
Bus Device Trouble Restoral 374
3
ROM Fault 375
3
Bell Trouble 376
3
Bell Restoral 377
3
Walk Test End 378
3
Walk Test Start 379
3
Bus Device Missing 380
3
Bus Device Missing Restoral 381
3
Battery Missing 382
3
Battery Missing Restoral 383
3
RAM Checksum Failed 384
To modify only a specific report, enter a
value in that report’s item number.
0 = Neither route
1 = Route 1 only
Primary and Backup (if programmed)
2 = Route 2 only
Primary and Backup (if programmed)
3 = Both routes
Primary and Backup (if programmed)
3
Global Report Routing Items
Programming Item
Item
Number
Description (Range) Entry
Communicator Disable 304 0 = Enable reporting
1 = Disable reporting (local-only system)
0
Route Attempts 305
Enter the number of times the system attempts each
destination in the selected route if the first attempt fails
(1 to 20).
The system alternates between the primary and backup
destinations. If both destinations are programmed for the
selected route group, the number of attempts is doubled.
For example, if this item is set to 10, the system tries the
primary destination 10 times and the backup destination 10
times for a total of 20 attempts.
10
Send Reports During Walk
Test
306 0 = No reports are sent during Walk Test
1 = Only Walk Test Start and Walk Test End reports are
sent during Walk Test
0
Default
= Country-specific default. Select this programming item to hear the updated default value.