Easy Series (ICP-EZM2) | Installer Guide | 7.0 Reference Materials
74 Bosch Security Systems, Inc. | 5/07 | F01U025147-01
7.8 Specifications
Enclosure
Dimensions (H x W x D): 37 cm x 31.8 cm x 8.5 cm (14.5 in. x 12.5 in. x 3.4 in.)
Construction Material: Cold-rolled steel, zinc seal, 0.36 mm thick (20 Ga.)
Environmental Considerations
Relative Humidity:
93% at 32°C ± 2°C (+90°F ± 2°F)
Operating Temperature: -10°C to +49°C (+14°F to +120°F)
• UL: 0°C to +49°C (+32°F to +120°F)
• CE: -10°C to +40°C (+14°F to +104°F)
Storage Temperature: -10°C to +55°C (+14°F to +130°F)
Supervised Points
On-board Hardwire: 8
• Single or dual end-of-line (EOL) tamper point support
• Point 1 supports two-wire smoke detectors
• All points support four-wire smoke detectors
• Enclosure tamper input (does not reduce point capacity)
Programmable Outputs (PO)
On-board: 4
• PO 1 only: Configurable relay
• PO 2 to PO 4: Configurable solid state
• PO 4 only: Internal supervised speaker driver option
PO 1 Relay Rating:
• Contacts: 2 A with no jumper installed; resistive loads only
• Output: 1.2 A with jumper installed; resistive loads only
• Operating Voltage: 30 VDC maximum
PO 2 to PO 4 Rating: 400 mA current sink
Control Center
Dimensions (H x W x D): 12 cm x 17.7 cm x 2.5 cm (4.7 in. x 7 in. x 1 in.)
Total Number Supported: 4
Recommended Mounting Surface: Non-metallic surface
Minimum Mounting Distance: 1.2 m (4 ft) between each control center
Current Draw: 110 mA standby; 165 mA alarm
Minimum Wire Length: 3 m (10 ft)
Maximum Wire Length:
Total: 400 m (1312 ft) using using 0.8 mm (#22 AWG) wire;
Single run: 100 m (328 ft) using 0.8 mm (#22 AWG) wire
Data Bus Wire Type Options:
• 1 four-conductor, power-limited 1.2 mm (#18 AWG) or 0.8 mm (#22 AWG)
wire
• At least 0.6 mm (#24 AWG) twisted pair CAT5 wire
UL installations require power-limited wiring.
Audio Bus Wire Type Options:
• 1 two-conductor or 1 four-conductor, power-limited 1.2 mm (#18 AWG) or 0.8
mm (#22 AWG) wire. Only two conductors are used.
• At least 0.6 mm (#24 AWG) twisted pair CAT5 wire
UL installations require power-limited wiring.
Unless using CAT5 cable, audio bus connections require a dedicated wire.
CAT5 Wire Requirements: Refer to Section 2.3 Control Center Installation on page 10.
Number of...
Users: 22
• User 1: Master user
• Users 2 to 21: System users
• User 22: Duress user
Events: 500 history events, stamped with time and date
Tokens and Key Fobs: One per user (User 22 does not receive a token or key fob)