Enter the number of times the system repeats a voice report during the phone call.
204. Voice Format Message Delivery Attempts
Enter how many times the system attempts to deliver a voice format message.
217. Emergency Call Override Number Delay
Enter the amount of time the system waits before sending reports if an emergency number is
dialed.
222. Phone Answer Ring Count
Enter the number of rings before the system answers an incoming call.
223. Bell Test
This programming item applies to all Intrusion output functions and to all arming modes.
0 = No closing ring-back or bell test; 1 = Enabled
If closing reports are disabled, the outputs turn on for 1 sec at the end of Exit Delay.
If closing reports are enabled, the outputs turn on for 1 sec when the control panel receives a
closing report acknowledgement from the central station.
Select the hour when the control panel calls RPS.
225. RPS Automatic Call in Time (Minutes)
Select the minute when the control panel calls RPS.
227. RPS Automatic Call in Time (Day of Week)
Select the day of the week when the control panel calls RPS.
228. RPS Automatic Call in Time (Day of Month)
Select the day of the month when the control panel calls RPS.
229. RPS Automatic Call in Phone Number
Enter the phone number that the control panel uses to call RPS.
245. RPS Automatic Call in Method
Select whether the control panel uses a phone number or an IP address to call RPS.
246. RPS Port Number
Enter the port number for contacting RPS when the automatic call in occurs over a network
connection.
305. Route Attempts
Enter the number of times the system attempts each destination in the selected route if the
first attempt fails.
601. Key Fob Duress
Select whether or not a wireless key fob sends a Duress event when the Arm and Disarm
buttons are pressed and held together.
611. Output 1 Type
Disabled: Output is disabled.
Intrusion: Output turns on when intrusion alarm occurs. To turn off output, turn off
system, or wait until end of intrusion bell cut-off time.
Fire: Output turns on when a fire alarm occurs. To turn off output, turn off system if it is
already on, or wait until end of fire bell cut-off time.
Fire Latching: Output turns on when a fire alarm occurs. To turn off output, turn off
system if it is already on, or acknowledge alarm if system is off.
Intrusion and Fire: Output turns on when an intrusion or fire alarm occurs. To turn off
output, turn off system, or wait until end of bell cut-off time. Fire alarms take priority over
intrusion alarms.
Intrusion and Fire Latching: Output turns on when an intrusion or fire alarm occurs. To
turn off output, turn off system if it is already on, or acknowledge alarm if system is off.
Fire alarms take priority over intrusion alarms.
Easy Series Control Panel
Programming Details and Defaults | en 109
Bosch Security Systems, Inc. System Reference Guide 2014.09 | 01 | F.01U.306.221