Callout Description
4 B426 Network
Interface Module
Use address 6.
5 B450 Conettix
Plug-in
Communicator
Use address 6.
6 Supervised Points
(single EOL)
Normally open and normally closed options (2.2k Ω)
7 Supervised Points
(dual EOL)
Normally closed (2.2k Ω)
8 Keyswitch Options (single and dual EOL) ((2.2k Ω)
9
Prog Output (PO) 1
Options
Switched 12v Switched Ground Dry Contact
10 Prog Outputs 2 - 4 NF A2P requires that sirens have a backup battery. When this
siren requires a 14,1V to 14,4V supply, use the optional board
EZPS-FRA or the auxiliary power supply IPP-PSU-2A5. Set the
output as interior burglary alarm.
11 2-wire Smoke
Detector Option
EOL resistor (P/N: 25899) required.
12 4-wire Smoke
Detector Option
EOL resistor (P/N: 25899) and Bosch EOL relay module
required
Note: The system uses a 12 VDC battery, connected as shown.
Easy Series Control Panel
Overview | en 19
Bosch Security Systems, Inc. System Reference Guide 2014.09 | 01 | F.01U.306.221