EasyManua.ls Logo

Bosch ICP-EZM2 - Communicator Programming Items

Bosch ICP-EZM2
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming Item Item
Number
Selections Manuf.
Default
Missing Wireless Device Conditions 162 0 = Creates a tamper condition (required for
EN50131-compliant countries).
1 = Creates a trouble condition.
0
Silence Trouble Tones 163 0 = All trouble tones announced
1 = Fire and 24-Hour trouble tones announced
0
System Inactivity Time (Hours) 164 0 to 255 0
System Inactivity Time (Days) 165 0 to 255 0
System Inactivity Time (Weeks) 166 0 to 255 0
Force Arm/Exit Error 167 0 = Off-normal points create an Exit Error at the
end of Exit Delay
1 = Off-normal points are force armed at the end of
Exit Delay
0
Audio Verification Command Set 168 0 = Complies with SIA AV-01-1997.11
1 = Use alternate verification command set
Key Fob Duress 601 0 = Duress event disabled
1 = Duress event enabled
0
Key Fob Button Configuration
616 0 = Status request only
1 = Turn system on (occupied)
2 = Turn system on (custom protection)
3 = Turn output on or off
4 = Turn output on for 2 sec.
0
Key Fob Button Configuration
626 0
Default = Country-specific default. Select this programming item to hear the updated default value, or refer to
Country Code Specific Default Programming Codes, page 112.
Communicator Programming Items
Notice!
To enable reporting, configure the following programming items:
Account Number (Expert Programming Item Number 100)
Route 1 Primary Destination (Expert Programming Item Number 206)
Format for Route 1 Primary Destination (Expert Programming Item Number 211)
Route Destination Items
Programming Item Item
Number
Selections Manuf.
Default
Account Number 100 4 or 6 digits, using 0 to 9 and B to F.
Refer to Report Configuration, page 45 for account
number, phone number, and IP address entry
instructions.
000000
Phone Line Supervision 201 0 = Unsupervised.
1 = Supervised.
0
5.2.3
Easy Series Control Panel Programming | en 51
Bosch Security Systems, Inc. System Reference Guide 2014.09 | 01 | F.01U.306.221