Programming Item Item
Numbe
r
Manuf.
Default
Programming Item Item
Numbe
r
Manuf.
Default
Bus Device Tamper Restoral 370 3 RAM Checksum Failed 384 3
1
Enter a value to globally set all of the following reports to the same entry.
2
To modify only a specific report, enter a value in that report's item number.
0 = Neither route
1 = Route 1 only; Primary and Backup
2 = Route 2 only; Primary and Backup
3 = Both routes; Primary and Backup
3
To enable the control center's emergency buttons, set Expert Programming Items 889, 888, and 890.
Global Report Routing Items
Programming Item Item
Number
Selections Manuf.
Default
Communicator Disable 304 0 = Enable reporting
1 = Disable reporting (local-only system)
0
Route Attempts 305 1 to 20 10
Send Reports During Walk Test 306 0 = No reports
1 = Only Walk Test Start and Walk Test End reports
0
Default = Country-specific default. Select this programming item to hear the updated default value, or refer to
Country Code Specific Default Programming Codes, page 112.
Point Programming Items
Programming Item
Number
(bold digits = Point
Number)
Programming Item Selections
9011, 9021, 9031,
9041...9101...9151...9201..
.9321
Point Type 0 = Disabled
1 = Perimeter
2 = Interior
3 = Perimeter Instant
4 = 24-Hour
5 = Fire Verified*
6 = Fire Instant
7 = Silent Panic
8 = Interior Walkthrough
9 = Perimeter Exit Cancel
11 = Momentary Keyswitch
12 = Maintained Keyswitch
13 = 24-Hour Trouble
14 = User Emergency
9012, 9022, 9032,
9042...9102...9152...9202..
.9322
Circuit Style 0 = Dual 2.2 kΩalarm and tamper circuit
2 = Single 2.2 kΩalarm circuit
5.2.6
Easy Series Control Panel Programming | en 57