Tempered 3.2 mm to 6.4 mm
(1/8 in to 1/4 in)
Laminated 3.2 mm to 6.4 mm
(1/8 in to 1/4 in)
Wired 6.4 mm (1/4 in)
Minimum pane size for all
types of glass
1.2 m (4 ft)
Microphone Omni-directional 360゚ electret
Operating
Temperature
Functional range: -10°C to +49°C (+14°F to +120°F)
EN 50130-5 Class II only: -10゚C to 40゚C (+14゚F to +104゚F)
Relative Humidity 0% to 93% (non-condensing)
Wall and Cover
Tamper Switch
Transmits a tamper signal when someone removes the device from
its base or pulls it away from the wall.
Frequency 433.42 MHz
Table 8.5: Specifications
Installation considerations
For the best detector performance, select a mounting location that is:
– Mounted on the ceiling within a maximum range of 20 ft (6 m)
– For armor-coated glass installations, mount the sensor no more than 12 ft (3.65 m) from
the glass
– Mount the detector in the direct line of sight of the glass to be protected
– On an opposite, or adjoining wall, within a range of 20 ft (6 m) for plate, tempered,
laminated, and wired glass
– In a suitable environment: temperature between -18 and 50゚C (0 and 120゚F); and
humidity between 10 and 90% non-condensing
Avoid mounting the detector in:
– Glass airlocks and glass vestibule areas
– Humid rooms
– Small utility rooms
– Rooms with noisy equipment (white noise) such as air compressors, bells, and power
tools
– Rooms smaller than 10 ft x 10 ft (3 m x 3 m)
– Rooms with lined, insulating, or sound supressing drapes
– A corner of a room
Avoid locations that expose the detector to possible false-alarm sources such as:
– Glass airlocks and vestibule areas;
– Kitchens;
– Corner mounting;
– Residential car garages;
– Stairwells
– Bathrooms; and
– Small acoustically live rooms
8.7.1
78 en | Device Specifications and Overview Easy Series Control Panel
2014.09 | 01 | F.01U.306.221 System Reference Guide Bosch Security Systems, Inc.