2.1 m (7.0 ft) -9 -6
2.4 m (8.0 ft) -10 -7
Notice!
The mounting height must be 2 m (6.5 ft) and the vertical angle must be set at -5for
installations containing pets.
The vertical adjusting screw must be securely tightened after setting the angle.
Sensitivity settings
Standard sensitivity
Use this setting when pets are present in the monitored area. Standard sensitivity provides
excellent detection performance and is the least sensitive to false alarms.
Intermediate sensitivity
Only use this setting in non-pet installations with minimal environmental disturbances.
Intermediate sensitivity provides the highest level of detection performance.
Walk testing
Notice!
To maximize battery life, the LED elements do not activate unless the unit is in the Walk Test
mode.
Perform a walk test to determine the boundaries of the coverage area. Perform this test at the
time of installation and monthly thereafter. To ensure continual daily operation, instruct the
end user to walk through the far end of the coverage pattern. This ensures an alarm output
prior to arming the system.
Start Walk Test mode from the detector. Insert a slotted screwdriver to open the detector
cover and then close the detector cover to start a 90-sec Walk Test mode.
Notice!
In the normal operating mode, an alarm can be transmitted only after three (3) minutes have
passed since the previous alarm restoral. This 3 minute lockout time reduces unnecessary RF
transmissions in high traffic areas, thereby extending battery life.
During this test mode, motion detected within the detector’s coverage area causes a
transmitted alarm and LED activation. Each alarm will also extend the Test Mode. Watch for
the green LED to indicate the edges of the Microwave pattern. Adjust as necessary.
Please reference the LED table below for LED descriptions.
LED Condition Cause
Steady LED PIR activation (Walk Test)
Steady green Microwave activation
Steady blue Alarm signal
8.8.2
8.8.3