Battery replacement Duracell DL123A, Panasonic CR123A, or Sanyo CR123A.
Check your battery yearly to ensure proper functionality.
Battery life Up to 5 years
Device testing To ensure proper functionality, the device must be tested
at least once every year by an installer.
Wall and cover tamper switch Transmits a tamper signal when someone removes the
device from its base or pulls it away from the wall.
Frequency 433.42 MHz
Table 8.8: Specifications
Walk testing
Perform a walk test to determine the boundaries of the coverage area.
Insert a slotted screwdriver into the designated hole to open the cover and then close the
detector cover to start a 90-sec Walk Test mode.
During this test mode, motion detected within the detector’s coverage area causes a
transmitted alarm and LED activation. Each alarm will also extend the Test Mode. Adjust as
necessary.
Notice!
Excessive use of the Walk Test Mode may reduce battery life. Use only for initial setup and
maintenance testing.
Notice!
In the normal operating mode, an alarm can be transmitted only after three (3) minutes have
passed since the previous alarm restoral. This 3 minute lockout time reduces unnecessary RF
transmissions in high traffic areas, thereby extending battery life.
Refer to the LED table below for LED descriptions.
LED condition Cause
Steady blue PIR activation (Walk Test)
Flashing blue Warm-up period after power-up
Flashing blue (four-pulse sequence) PIR failure. Replace unit.
8.10.1
86 en | Device Specifications and Overview Easy Series Control Panel
2014.09 | 01 | F.01U.306.221 System Reference Guide Bosch Security Systems, Inc.