Control Panel Operating Commands | en 11
Bosch Security Systems, Inc. Quick Reference Guide 2014.06 | 02 | F01U298027
Operating Commands
The system supports programmable 1- 4- digit Installer and User Code to execute the
following operating commands.
Notice!
No identical User Codes are allowed. User Codes are not permitted to be the same as
Installer codes.
Description Command (Default User Code =
2580
Default Inst. Code = 1234)
Installer
Code
User Code with
Authority
Levels
Arm in AWAY Mode [Code] + [#]
[Code] + [0] + [#] (arm all areas)
Long press [#]
Arm in STAY Mode 1 [Code] + [*]
Long press [*]
Arm in STAY Mode 2 Long press [0]
Disarm in AWAY Mode [Code] + [#] or [Code] + [*]
[Code] + [0] + [#] (disarm all areas)
Long press [#] (only if no alarm)
Disarm in STAY Mode 1 [Code] + [#] or [Code] + [*]
[Code] + [0] + [#] (disarm all areas)
Long press [*] (only if no alarm)
Disarm in STAY Mode 2 [Code] + [#] or [Code] + [*]
[Code] + [0] + [#] (disarm all areas)
Long press [0] (only if no alarm)
Add/Delete RF Devices [Code] + [0] + [#]
Add/Delete RF Keyfob/
Repeater (ICON codepad only)
[Code] + [0] + [#]
Set First Test Report [Code] + [1] + [#]
Add/Delete User Code/RF
Keyfob
[Code] + [1] + [#]
Change Domestic Telephone
Numbers
[Code] + [2] + [#] √√
Change Telco Arm/Disarm
Sequence
[Code] + [3] + [#] √√
Set STAY Mode 2 Zones [Code] + [4] + [#] √√
Turn Outputs On/Off [Code] + [5] + [#]
3