12 en | Operating Commands Control Panel
2014.06 | 02 | F01U298027 Quick Reference Guide Bosch Security Systems, Inc.
Description Command (Default User Code =
2580
Default Inst. Code = 1234)
Installer
Code
User Code with
Authority
Levels
Report Monitor Mode [Code] + [6] + [#] √
Setting Date and Time [Code] + [6] + [#] √
Walk Test Mode [Code] + [7] + [#] √√
Event Memory Recall [Code] + [8] + [#] √√
Duress Disarm [Code] + [9] + [#] or [Code] + [3] +
[#]
√
Zone Bypass (Zone Isolating) [*] + [Code] + [*] √
System Reset [Code] + [9][9][8][9] + [#] √
Enter User Menu (text codepad
only)
[Code] + [-] √
Enter Programming Menu [Code] + [#] or [Code] + [-] √
Enter User Menu [-]
Exit Menu Without Saving
changes
Long press [-]
Codepad Panic Alarm Press [1] and [3] or [*] and [#]
Codepad Fire Alarm Press [4] and [6]
Codepad Medical Alarm Press [7] and [9]
Speaker Test Long press [1]
Bell Test Long press [2]
Strobe Test (Toggle On/Off) Long press [3]
Day Alarm (Toggle On/Off) Long press [4]
Fault Analysis Long press [5]
Modem Call (A-Link Plus) Long press [6]
Latching Output (Reset) Long press [7]
Display Codepad ID/Change
Codepad Buzzer Tone
Long press [8]
Test Report Long press [9]
Table 3.1: Operating Commands