Control Panel Operating Commands | en 16
Bosch Security Systems, Inc. Quick Reference Guide 2014.06 | 02 | F01U298027
Fault Analysis Mode
If a fault occurs, the FAULT or MAINS indicators flash and the codepad beeps once every min.
If the AC MAINS supply fails, the MAINS indicator flashes until the AC MAINS supply is
restored. Pressing the [#] button once acknowledges the fault and stops the codepad from
beeping once every min.
How to Determine the Type of System Fault
To determine which system fault occurred, enter Fault Analysis Mode by following the steps
below:
1. Hold down the [5] key until two beeps sound. The FAULT indicator remains steady and
the STAY and AWAY indicators flash in unison. A zone indicator displays the type of fault
that occurred (for example, Zone 1 = System Fault). Refer to Fault Indicators
of possible system faults.
2. To further determine the type of fault condition, press and hold down the key that
corresponds to the zone indicator displayed. For example, if Zone 1 displayed System
Fault, press and hold the [1] key to display which system fault occurred.
3. To exit Fault Analysis Mode and return to the disarmed state, press the [#] key. The
FAULT indicator continues to display and the codepad stops sounding once a min.
Fault Indicators
Zone
Indicator
Fault Description Hold Down
Button
Zone
Indicator
Fault Condition
1 System Fault 1 1
2
3
4
5
7
8
9 to 16
Battery Fail
Date and Time
RF Receiver Fail
Output 1 to 3 Fail
Telephone Line Fail
Power Supply Fail
Tamper
RF Repeater 1 to 8 Fail
2 RF Low Battery 2 1 to 16 Zones 1 to 16 RF Low Battery
3 Zone Tamper Alarm 3 1 to 16 Zones 1 to 16 Tamper Alarm
4 Sensor Watch Fault 4 1 to 16 Zones 1 to 16 Sensor Watch Fail
5 RF Sensor Watch 5 1 to 16 Zones 1 to 16 RF Sensor Watch Fail
6 Communication Fail 6 1
2
3
4
Receiver 1 Fail
Receiver 2 Fail
IP Module 1 Fail
IP Module 2 Fail
3.11
7 Output and
Codepad Fail
72
3 to 6
Output Expander Fail
Codepad Fail
8 Keyfob Low Battery 8 1 to 16 Keyfob 1 to 16 Low Battery
for the list