Ring Count
Item Location Option Default New
Ring Count 0175 0 = Panel does not answer
1 - 13 = No. of rings until panel answers
14 = Answering machine bypass 2
15 = Answering machine bypass 1
8
Telephone Line Fail Options
Item Location Option Default New
Telephone Line Fail
Options
0176 1 = Display FAULT Indicator when
telephone line fails
2 = Sound alarm when system is armed
4 = Sound alarm when system is
disarmed
8 = Reserved
0
Notice!
Option 2 and 4 must be used in conjunction with Option 1 (for example, program 1,3,5, or 7).
Dialer Options 1
Item Location Option Default New
Dialer Options 1 0177 1 = Dialer reporting functions allowed
2 = Remote arming by telephone allowed
4 = Answering machine bypass only when
armed
8 = Use Bell 103 for FSK format (Disabled
= CCITT V21)
9
Dialer Options 2
Item Location Option Default New
Dialer Options 2 0178 1 = Arm/Disarm Reports only if alarmed
2 = STAY Mode Arm/Disarm Reports
Enable
4 = Delay siren until transmission
complete
8 = Extend handshake wait time from 30
to 60 sec.
0