Loading...
Item Location Default New RF Zone Option
Location
Default New
RF Zone #13 1940 - 1947 0 1948 - 1949 0
RF Zone #14 1950 - 1957 0 1958 - 1959 0
RF Zone #15 1960 - 1967 0 1968 - 1969 0
RF Zone #16 1970 - 1977 0 1978 - 1979 0
Item Option
RF Zone Option 0 = All Used
1 = Input 1
2 = Input 2
3 = Input 1 & 2
4 = Input 3
5 = Input 1 & 3
6 = Input 2 & 3
7 = Input 1 & 2 & 3
8 = Input 4
9 = Input 1 & 4
10 = Input 2 & 4
11 = Input 1 & 2 & 4
12 = Input 3 & 4
13 = Input 1 & 3 & 4
14 = Input 2 & 3 & 4
15 = Input 1 & 2 & 3 & 4
Table 4.5: RF Zone Options
RF Repeater ID Numbers
Item Location Default New Item Location Default New
RF Repeater #01 1980 - 1987 0 RF Repeater #05 2020 - 2027 0
RF Repeater #02 1990 - 1997 0 RF Repeater #06 2030 - 2037 0
RF Repeater #03 2000 - 2007 0 RF Repeater #07 2040 - 2047 0
RF Repeater #04 2010 - 2017 0 RF Repeater #08 2050 - 2057 0
Text Codepad Items
Notice!
Refer IP Destination, page 36 to enter sensitive alphanumeric characters with text codepad
IUI-SOL-TEXT .
Home Message
Item Location Default New
Home Message 2500 - 2535 Bosch Security Co.
Zone Names
Item Location New Item Location New
Zone 1 Name 2536 - 2559 Zone 9 Name 2728 - 2751
Zone 2 Name 2560 - 2583 Zone 10 Name 2752 - 2775
Zone 3 Name 2584 - 2607 Zone 11 Name 2776 - 2799
Zone 4 Name 2608 - 2631 Zone 12 Name 2800 - 2823
4.21
4.22
4.22.1
4.22.2
Control Panel Programming Parameters | en 4
Bosch Security Systems, Inc. Quick Reference Guide 2014.06 | 02 | F01U298027