65
Workshop Manual
Smart Tachograph EFAS-4.10/4.11
SrvID
hex
EFT
hex
DTC Symbol
Display text
Description and trouble-shooting
S43
19
31 40 00 000F00
Internal Device
malfunction
Meaning / Cause:
Malfunction of the keyboard has been detected, i.e. at least one
key remains continuously pressed. The tachograph assumes that
a key has been pressed continuously if it remains pressed for
more than two minutes.
Measures:
Check if the keys are being blocked. Devices, in which the keys
are blocked permanently must be replaced.
S44
19
33 40 00 001030
Display
malfunction
(the text output: “ service
display fault”, appears addi-
tionally on the printer)
Meaning / Cause:
A malfunction of the LCD display has been detected, i.e. the
communication for display has malfunctioned or is permanently
interrupted. There is either no picture on the display (no charac-
ters visible) or it is faulty (ickering, pixel errors, etc.).
Measures:
Devices, in which this fault occurs permanently or in which visible
defects can be seen in the picture displayed, must be replaced.
Remarks:
If the display is too faint then the contrast and brightness must
be adjusted in the corresponding setup menu. In this case,
however, there is no malfunction reported.
S45
19
35 40 00 002508
Sensor
malfunction
Meaning / Cause:
The motion sensor has reported an internal fault to EFAS.
Measures:
If this fault occurs repeatedly then the tachograph must be
replaced.
S46 - - 40 00 003100 - - - Meaning / Cause:
Tachograph malfunction, pin B5.
Remarks:
Reserved code (not supported by EFAS).
S47
19
- - 40 00 003200 - - - Meaning / Cause:
Tachograph malfunction, pin B6.
Remarks:
Reserved code (not supported by EFAS). The pin is electrically
connected to the pins B7 and D6. Please see the description of
service ID 48.
S48 31 40 00 003000
Internal Device
malfunction
Meaning / Cause:
Tachograph malfunction, pin B7 (speed signal).
The monitoring circuit of the signal at this output of the recording
equipment has detected a malfunction.
Measures (continued):
Check B7 for short-circuit and measure the signal level. Measure
the pulses at the output B7 and compare them with the input
impulses from the motion sensor at the input B3. The pulse
frequency must be identical, the pulses at the output B7 are
normalized by the taking the value of the k-factor that has been
congured into consideration. Check the connection between
output B7 and the controller connected.
S66 81 ---
! Manufacturer
specic Event
Meaning / Cause:
EFAS was opened with authorization using a workshop
smart-card.
Measures:
The opening must be marked in the repair protocol and protocol
must be archived.
19 The EFT for this event or the malfunction is not stored to the mass memory in the CALIBRATION operating mode. Information appears in the display with the specication of the
SrvID that this event or malfunction has been detected for a short duration.