26
Workshop Manual
Smart Tachograph EFAS-4.10/4.11
6.4.1.4 Subsequent entry of the ocial number plate
In order for the vehicle to be allowed to
participate in trac on public roads, the
ocial registration plate must be entered
in the calibration data. If this is not done
before activation or during the initial cal-
ibration, the vehicle registration number,
the addendum may be made in two ways:
y By the vehicle owner using his company
card. The generates the calibration
purpose (5).
y Or through a workshop. This generates
the calibration reason (4) “verication.
Attention: According to the law, a
complete calibration must be per-
formed including a new seal for
the encoder. An addendum of the
authorising Member State and the
vehicle registration number alone is not
permitted by law.
- registering member state and vehicle registration number
- calibration purpose (5) „registration number”
6.4.1.5 Other calibration purposes
Value assignments for calibration purposes can be found in appendix: Purposes of calibration.
The calibration reasons (1) Activation, (2) “Initial installation and (5) “Entry of the ocial number plate by a company have
been described above.
A data set with the calibration reason (4) “Regular verication is written with each recalibration. (If more than two calibrations
are performed on a calendar day, only the rst and last ones remain.
The record with the calibration reason (128) “Plombenwechsel” indicates when the last time a seal number was changed.
The calibration purpose (6) is written when a time adjustment of more than 20 minutes is made and no recalibration is carried
out thereafter. However, the law requires a complete recalibration if there is a time deviation of more than 20 minutes.
The calibration reason (3) is written when the tachograph is installed in another vehicle (new VIN).