Common applications of KBR boilers
Greenstar FS/Combi FS – 6 720 810 590 (2020/04)
30
5.2 Multiple zones using circulators with DHW
Fig. 13 Piping
[1] Supply to heating zone 2
[2] Pump heating zone 2
[3] Supply to heating zone 1
[4] Pump heating zone 1
[5] Supply to indirect tank
[6] DHW pump
[7] Drain/Bleed point
[8] Boiler supply pipe 1¼ "
[9] Low Loss Header
[10] Heat only boiler
[11] Boiler return pipe 1¼ "
[12] Return from indirect tank
[13] Return from heating zone 1
[14] Return from heating zone 2
[15] Grain/Bleed point x3
[16] Combination fast fill/back flow preventer
[17] Expansion (tank) vessel
5.2.1 To utilize the LLH
Switch off and isolate the boiler
Drain the boiler
Remove front panel
Locate the LLH at the left-hand side of the lower section of the boiler
1. Unscrew the cap [a] from the body of the LLH [c]
This will break the label across the cap and body indicating that
the LLH has been employed
2. Withdraw the cap [a] and plunger assembly [b]
3. Unscrew the plunger assembly [b] from the cap [a],
4. Set the plunger assembly [b] aside
5. Re-fit the cap [a] without the plunger assembly [b]
6. Tighten the cap [a] and ensure it is secure.
Fig. 14 Utilizing the LLH