1 689 989 349 2017-07-01| Robert Bosch GmbH
enInitial Commissioning | KMA 802/822 | 11
4.3 KMA 802 (measuring device)
Fig. 10: Measuring device
1. Attach the plate (fig. 10, item 7) to the swivel arm,
ensuring that the guide pipe (fig. 10, item 6) is
pointing outwards (pointing away from the clamping
bed).
2. Remove the cover (fig. 10, item 2) from the electro-
nics compartment.
3. Insert the gas spring (fig. 10, item 1), with the eye
pointing upwards, into the guide tube (fig. 10,
item 3) and position the complete measuring device
from above. Push the guide tube (fig. 10, item 3) on
the measuring device over the guide tube (fig. 10,
item 6) on the swivel arm.
4. Screw the eye of the gas spring (fig. 10, item 1) to the
guide tube (fig. 10, item 3) on the measuring device.
Raise the measuring device until the cross borehole in
the guide tube (fig. 10, item 3) and the eye borehole
in the gas-spring are in alignment and the hexagon-
socket head bolt can be inserted. Screw on the self-
locking nut.
5. Fit cover (fig. 10, item 2) to electronics compart-
ment.
6. Connect the enclosed hoses (fig. 10, item 4, 8) to
the bottom right and left and connect to the two
connections on the swivel arm. Tighten down termi-
nal (fig. 10, item 5).
4.4 Electrical connection
4.4.1 KMA 800/822
i The specification and assignment of the PC connec-
tions are described in the PC operating instructions.
1. Connect the keyboard cable to a vacant USB connec-
tion on the PC.
2. Video cable (15-pin connector) to the VGA socket
X9 (video) on the PC.
KMA 800:
1. Insert the PC power cable (230 V) into the X3 plug
connector on the EPS electrical cabinet.
2. Insert the monitor power cable (230 V) into the X3
plug connector on the EPS electrical cabinet.
3. 9-pin Connect sub-D connector X4 (COM2) of PC using
the RS232 connecting cable (3m) to 9-pin sub-D con-
nector X7 on the EPS electrical cabinet.
KMA 822 (trolley):
1. Insert PC power cable (230 V) in socket on the rear
panel of the trolley.
2. Insert the trolley power cable (230 V) into the X3
plug connector on the EPS electrical cabinet.
3. 9-pin Connect sub-D connector X4 (COM2) of PC
using the RS232 connecting cable (8m) to 9-pin
sub-D connector X7 on the EPS electrical cabinet.
4.4.2 KMA 802 (measuring device)
1. Insert connector X1 into 37-pin bush X2 in electrical
cabinet.
2. 9-pin Connect sub-D connector X2 of measuring
device using the RS 232 connecting cable (8 m) to
9-pin sub-D socket X3 (COM1) of the PC
(note designation).
4.4.3 Overflow temperature
¶ Connect temperature sensor to BNC socket X3 on
measuring device.