1 689 989 223 2016-12-15| Robert Bosch GmbH
Technical Data | KTS 560 / 590 (KTS 5a Series) | 25 |
7.6 Bluetooth Class 1
Wireless connection
KTS 560 / 590 to PC/Laptop
Minimum range
Workshop environment in the open
space
30 meters
If the vehicle door or window is open
and the engine is still running in the ve-
hicle interior
10 meters
en
7.3.2 AC and effective-value measurement
(CH1 and CH2)
1)
Property Value/range
AC frequency range 10Hz — 100kHz (-3dB)
Measuring range 200 mV — 30 V
AC accuracy at 100 Hz
RMS accuracy at ≤10kHz
±2% of measurement value, ad-
ditional
±0.5% of measurement range
Resolution 100µV — 100mV
(depending on measuring
range)
1)
The measuring ranges in measurement modes "U" and "I" are
given as peak-to-peak values. Consequently, the digital display
box is "grayed out" if the set measuring range is briefly exceeded
(overload).
7.3.3 Resistance measurement (CH1)
Property Value/range
Measuring range 100 — 1M
Accuracy up to 200K ±1.25% of measured value
plus ±0.25% of measuring range
Accuracy up to 1M ±2% of measured value
plus ±0.25% of measuring range
Resolution 0.1 — 1000
(depending on measuring range)
Input resistance >9M
7.3.4 Current measurement (CH1 and CH2) with
100A / 600A current measuring clip (special
accessory)
Measurement up to Measuring range
100 A 20A, 50A, 100A
600 A 200A, 500A, 600A
7.3.5 Continuity tester (CH1)
Property Value/range
Measurement current 2mA
No-load voltage ≤ 5 V
Continuity <10 (with audible feedback)
7.3.6 Diode measurement (CH1)
Property Value/range
Measurement current 2mA
No-load voltage ≤ 5 V
Maximum diode voltage 4 V
7.4 Oscilloscope specifications
Measurement channel 1 (CH1) floating
Measurement channel 2 (CH2) floating
Input resistance > 900kohms.
Property Value/range
Measuring range 200mV — 60VDC, 30VAC,
42VACpeak
Coupling DC, AC,
DC(+) (only positive range is shown),
DC(-) (only negative range is shown).
Signal source CH1/CH2: U, 100A, 600A,
Diagnosis pins 1 to 15 (not pins 4, 5)
X-deflection 25 µs — 1 s
Trigger mode Manual, Auto-Time, Auto-Level
Trigger source CH1, CH2
Pretrigger time 0 % — 100 %
Frequency range > 1 MHz (typical 5 MHz)
Bandwidth 4MHz (with measuring lead)
Resolution
1)
12 bits at 1MS/s /
8 bits at 20MS/s
Sampling rate
1)
20MS/s
Memory depth per
channel
50 signal curves
with 512 – 2560 coordinates
1)
MS = Megasamples
7.5 Power supply unit
Property Value/range
Input voltage 100VAC— 240VAC
Input frequency 47Hz — 63Hz
Output voltage 15 V
Output current 1.66 A
Operating temperature 0°C — 40°C