EasyManua.ls Logo

Bosch PAM 220 - 7.2.1 Display elements; 7.3 Technical Data

Bosch PAM 220
183 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English | 23
Display elements
(a)
Measured value
(b)
Battery charge indicator/battery warning
(c) Supplementary angle indicator SUP
(d) Spring angle indicator SPR
(e) Corner angle indicator CNR
(f) Horizontal mitre angle indicator MTR
(g) Bevel angle indicator BVL
(h) Saved value indicator HOLD
Technical Data
Digital angle measuring device PAM 220
Article number
3 603 F76 ...
Measuring range 0°–220°
Measuring accuracy
Angle ±0.2°
Spirit level 1.5 mm/m
Calculated angle accuracy ±0.1°
Operating temperature –10 °C to +50 °C
Storage temperature –20 °C to +70 °C
Max. altitude 2000m
Relative air humidity max. 90 %
Pollution degree according to IEC61010-1 2
A)
Batteries 2×1.5V LR6(AA)
Operating time, approx. 25 h
Automatic switch-off after approx. 5 min
Leg length 400 mm
Weight according to EPTA-Procedure 01:2014 0.89 kg
Bosch Power Tools 1 609 92A 56P | (12.07.2019)