18 en | Installation PAVIRO Call Stations
2018.04 | 04 | F01U306899 Bosch Security Systems
5 Installation
5.1 Delivery condition
The call stations are programmed with the following factory
functions and properties settings:
Parameters Setting/description
CAN address 0 (disconnected)
CAN baud rate 10 kbit/s
CAN termination off
Name PVA-15CST / PVA-15ECS
Password Setup menu password-protected,
password: 2222
Prechime Off
Buzzer On (acoustic warning signal)
Compressor Off
Options Alarm buttons Not configured
Key switch Not configured
External
microphone
Not configured
Button
assignme
nt
Selection
buttons 1-n
Selection of zone 1 through n
(button 1 = zone 1, button 2 =
zone 2 etc.)
Call in selected zones/groups,
default priority 50
Switches system on/off, default
priority 40
Stops an active audio signal,
default priority 69