34 en | Configuration PAVIRO Call Stations
2018.04 | 04 | F01U306899 Bosch Security Systems
Notice!
The default password for activation of the CST Setup Menu is
2222. The password can be changed in the IRIS-Net software.
7.2 Setup menu
This section describes the CST Setup Menu of the PAVIRO call
station.
CAN Address
Pressing the button takes the user to the CAN Address dialog.
Pressing the or button sets the required CAN address. The
call station can be assigned a CAN address between 1 and 16.
Pressing the button accepts the address selected, and returns
the user to the CST Setup Menu.
Notice!
Address 0 (delivery status) disables remote communication
between the call station and the PVA-4CR12 . The call station
does not appear in the system, even though it is physically
connected to the CAN bus. Each CAN address may exist only
once at a PVA-4CR12 . Otherwise, network conflicts may arise.
CAN Baudrate
Pressing the button takes the user to the CAN Baudrate
dialog. Pressing the or button toggles between the available
baud rates. Pressing the button accepts the setting selected,
and returns the user to the CST Setup Menu.
CAN Termination
Pressing the button takes the user to the CAN Termination
dialog. Pressing the or button activates or deactivates the
termination on this call station. Termination must be activated
on the call station that is connected to the end of the CAN bus.
Pressing the button accepts the setting selected, and returns
the user to the CST Setup Menu.