en | Installation
PAVIRO End-of-line supervision
module
2019-01 | V2 | F01U350870 Bosch Security Systems B.V.
6 5 4 3 2 1 Module
address
DIP switch S2 DIP switch S1
4 3 2 1 4 3 2 1
set the switch
to OFF and
back to ON.
Tab.2.1: DIP switch settings on the module (the settings on delivery are
shown in bold)
Notice!
The module address must be unique within each zone
topology (each controller, router, or amplifier).
Connect the module to the speaker line
Connect the speaker line wires to the plus (+) and minus (-) contacts of
the connector. Make sure the capacitance limit of parallel connected
speaker lines is not exceeded, as described in Technical data, page 10.
Connect the module to earth or ground
Use the earth contact on the connector to connect the module to earth
or ground. To make this connection, you can use:
a short wire to earth or ground near the installed module,
the cable shield, or
any free wire on the cable.