PAVIRO Call Stations Operation | en 37
Bosch Security Systems 2018.04 | 04 | F01U306899
Indicator
light
Status Description
Illuminated green Pressing the button ends an
event that has already started
↵ (the
function
of this
indicator
light is
configura
ble in
IRIS-Net)
Off The selected zones are free
and a call can be made
Illuminated green
while the speaker
button is pressed
The announcement is being
transmitted
Green, flashing A call station with lower
priority is currently
transmitting an
announcement in at least one
selected zone – this
announcement can be
interrupted at the cost of the
currently active call station
Green, flashing
quickly
– At least one of the
selected zones or groups
is occupied with higher
priority (announcement,
chime, alarm) and
cannot be interrupted
– A call that has already
started will be
interrupted by the higher
priority
POWER Off The call station power supply
has been deactivated/
interrupted
Illuminated green The call station power supply
is functioning correctly