7
¡ In recesses of 500mm, the appliance must be in-
stalled on the front edge of the recess.
¡ Seal the cut surfaces of wooden work surfaces with
a special glue seal to protect them from moisture.
¡ Any adjoining vertical wall surface situated within
200mm from the edge of any cooktop burner must
be a suitable non-combustible material for the entire
length of the cooktop, in accordance with clause
6.10.1.2 of AS/NZS 5601.1.
2.3 Clearances
¡ A range hood fitted above the top must be installed
according to the installation instructions for the
range hood. A minimum distance of 650mm is re-
quired for a range hood and 750mm for an exhaust
fan.
¡ Any combustible construction above the cooktop
must be at least 650mm above the top of the
burner and no construction shall be within 430mm
above the top of the burner.
¡ Height of the pan support above the worktop sur-
face: up to 60mm.
¡ A minimum depth of 50mm from the top of the
worktop surface must be provided for the appliance.
2.4 Shield
If the base of the hotplate can be touched, fit a protecting shield.
¡ The shield must be at least 10mm from the lowest
part of the hotplate and must be capable of with-
standing the appliance temperatures. Minimum
thickness of worktop is 30mm.
¡ The shield material must be mdf or similar with min-
imum thickness of 12mm.
¡ The shield overall dimensions must be 560mm
wide x 480mm deep.
¡ Provide cutout in right hand rear of shield of 80mm
wide x 80mm deep to provide for gas regulator /
LPG connection fitting.