Bosch Security Systems | 2006-06 | 9922 141 10377 en
Plena Voice Alarm System | Installation and User Instructions | IEC60849 en | 106
e The system shall be able to broadcast
attention- drawing signals and speech
messages to one or more areas
simultaneously. There shall be at least one
appropriate attention-drawing signal
alternating with one or more speech messages
for this purpose.
Compliant, if attention-drawing signal is part of the
configuration. Responsibility of the installer.
Note: It is recommended that an attention drawing
signal is assigned to the EMG button.
f At any time the system operator shall be able
to receive, by means of a monitoring system,
indications of the correct functioning or
otherwise of the relevant parts of the
emergency system (see also 5.2 and 5.3).
Compliant.
g Failure of a single amplifier or loudspeaker
circuit shall not result in total loss of coverage
in the loudspeaker zone served.
NOTE 1:
The monitoring system (specified in 4.1f)
should indicate the failure of an amplifier or of a
loudspeaker circuit.
NOTE 2:
Particularly in small buildings, it may not be
necessary to install two separate loudspeaker
circuits in one loudspeaker zone. A decision on
this matter may be subject to local regulations.
Compliant if installed with:
Spare Power Amplifiers.
Multiple loudspeaker circuits per zone or
multiple zones. A-B wiring.
Appropriate supervision on.
Responsibility of the installer.
h An attention-drawing signal shall precede the
first message for 4 s to 10 s. Successive
signals and messages shall then continue until
either changed in accordance with the
evacuation procedure, or manually silenced.
The interval between successive messages
shall not exceed 30 s and attention- drawing
signals shall be broadcast whenever periods of
silence might otherwise exceed 10 s. Where
more than one attention-drawing signal is
used, such as those used for different types of
emergency, each signal shall be clearly
distinguishable in character.
Compliant, if attention-drawing signal is part of the
pre- recorded message and the configuration has
been setup to include this signal. Responsibility of
the installer.
Note: if you deviate from this, the system is no
longer a certified system.
i All messages shall be clear, short,
unambiguous and as far as practicable, pre-
planned.
Responsibility of the installer. Default configuration
is compliant. Various messages are pre installed as
examples.
Where pre-recorded messages are used
they shall be held in a non-volatile form,
preferably in a solid- state store, and be
continuously monitored for availability.
Flash memory is monitored with checksum.
The system design shall make it inherently
impossible for an external source to
corrupt or derange the store or its
contents.
Compliant. Upload of a new configuration via
external PC is password protected. Other external
connections are not available.
NOTE:
On grounds of reliability, it is preferable not to
use storage media depending on mechanical
devices.
Storage medium is flash memory card.
j The language(s) used shall be specified by the
purchaser.
Responsibility of the installer.
table 1: IEC60849 - 4.1 Principal features
Requirement Compliance Signature