4.9 Connecting volume overrides
The controller has six 24V DC volume override
connectors, one for each loudspeaker zone (Z1 - Z6, see
figure 4.7). Volume override can be used to get a
business or emergency call through, regardless of local
volume controls. This can be useful in case local zone
volumes have been set to a low volume level. Both 4-
wire (see section 4.9.1) and 3-wire (see section 4.9.2)
override schemes are supported.
Internally, the positive override pins (Z+) are all
connected to either the NC or the NO contact of the
Volume Override output (see figure 4.8). The negative
override pins (Z-) are all connected to earth.