180 en | Troubleshooting PRAESENSA
2019.11 | V1.00 | Installation manual Bosch Security Systems B.V.
Music control not available on a call station
Cause: The Music function is not enabled in Device Options of that call station.
Action: Enable the Music function for that call station. If the music source is
connected to that call station, then also configure a BGM channel for the Audio input
of that call station in Zone definition > BGM routing.
One or more amplifiers are not powered on
Cause: The amplifier does not receive power from the multifunction power supply or
power supply module.
Action: Make sure the power supply is powered, that the power supply wiring is
connected correctly and that power supply outputs are enabled in the configuration.
The system controller is not powered on
Cause: The system controller does not receive power from the multifunction power
supply or power supply module.
Action: Make sure the power supply is powered, that the power supply wiring is
connected correctly and that power supply outputs are enabled in the configuration.
One or more call stations are not powered on
Cause: The call station does not receive PoE-power from the multifunction power
supply or switch.
Action: Make sure the power supply or switch is powered and that at least one of
the call station Ethernet cables is connected to a port that provides PoE. The second
port of the call station will not provide PoE power to a subsequent call station.
The yellow fault indicator on one of the devices lights up
Cause: There can be many reasons.
Action: A good way to start is to check the system fault log or the fault menu on the
call station for a more detailed fault description.