10 | English
– Turn the measuring tool 180° without adjusting the
height. Aim it at wallA such that the vertical laser line runs
through the already marked pointⅠ. Allow the measuring
tool to level in and mark the point where the laser lines
cross on wallA (pointⅢ).
– The discrepancy d between the two marked pointsⅠ and
Ⅲ on wallA reveals the actual height deviation of the
measuring tool.
The maximum permitted deviation on the measuring dis-
tance of 2×5m=10m is as follows:
10m×±0.1mm/m=±1mm. The discrepancy d between
pointsⅠ and Ⅲ must therefore amount to no more than
1mm.
Checking the levelling accuracy of the horizontal lines
For this check, you will need a free area of 5×5m.
– Mount the measuring tool in the middle between wallsA
and B on a tripod(24), or place it on a firm, level surface.
Switch on the measuring tool in the mode with automatic
levelling. Switch on horizontal mode with a laser line for-
wards and allow the measuring tool to level in.
– At a distance of 2.5m from the measuring tool, mark the
centre of the laser line on both walls (pointⅠ on wallA and
pointⅡ on wallB).
– Set up the measuring tool at a 5m distance and rotated
by 180° and allow it to level in.
– Align the height of the measuring tool (using the tripod or
by placing objects underneath as required) so that the
centre of the laser line exactly hits the previously marked
pointⅡ on wallB.
– Mark the centre of the laser line on wallA as pointⅢ (ver-
tically above or below pointⅠ).
– The discrepancy d between the two marked pointsⅠ and
Ⅲ on wallA reveals the actual horizontal deviation of the
measuring tool.
The maximum permitted deviation on the measuring dis-
tance of 2×5m=10m is as follows:
10m×±0.1mm/m=±1mm. The discrepancy d between
pointsⅠ and Ⅲ must therefore amount to no more than
1mm.
Checking the levelling accuracy of the vertical lines
For this check, you will need a door opening (on solid
ground) which has at least 2.5m of space either side of the
door.
– Place the measuring tool 2.5m away from the door open-
ing on a firm, flat surface (not on a tripod). Switch on the
measuring tool in the mode with automatic levelling.
Switch on vertical mode with a vertical laser line forwards
and aim the vertical laser line at the door opening. Allow
the measuring tool to level in.
1 609 92A 58T | (07.08.2020) Bosch Power Tools