18 | English
When transmitting data by means of Bluetooth®, time lags may occur between the mobile
device and the measuring tool. This can be due to the distance between the two devices
or the measurement object itself.
Activating the Bluetooth® interface for transmitting data to a mobile device
Ensure that the Bluetooth® interface is activated on your mobile device.
Press the(1) button to bring up the Bluetooth® menu and press the(1) button again (or
the (6) [+] button), to activate the Bluetooth® interface. If multiple active measuring
tools are found, select the appropriate measuring tool using the serial number. You can
find the serial number(11) on your measuring tool's type plate. The connection status
and the active connection(b) are displayed in the status bar(h) of the measuring tool.
Bosch applications are available to expand the range of functions. Depending on the
device, you can download these applications from the corresponding app stores.
Deactivating the Bluetooth® interface
Press the(1) button to bring up the Bluetooth® menu and press the(1) button again (or
the (3) [–] button), to deactivate the Bluetooth® interface.
Assembly
Inserting/changing the batteries
Using alkali-manganese or nickel metal hydride rechargeable batteries (especially at low
operating temperatures) is recommended for operation of the measuring tool.
With 1.2 V batteries, more measurements may be possible than with 1.5 V batteries, de-
pending on the capacity.
Press the locking mechanism (12) to open the battery compartment cover (13) and re-
move the battery compartment cover. Insert the batteries. When inserting, pay attention
to the correct polarity according to the representation on the inside of the battery com-
partment.
When the state of charge of the batteries or reusable batteries is low, a request to activ-
ate the battery saver mode will appear on the display. When the battery saver mode is
activated, the battery runtime will be extended and the battery symbol on the display will
have a yellow outline(see "“Settings” menu (see figure B)", page20).
When the empty battery symbol first appears on the display, only a limited number of
measurements is still possible. When the battery symbol is empty and flashes red, no fur-
ther measurements are possible. Replace the batteries or reusable batteries.
Always replace all the batteries at the same time. Only use batteries from the same man-
ufacturer and which have the same capacity.
1 609 92A 5YM | (19.01.2021) Bosch Power Tools