36/48 Operation
Bosch Rexroth AG, 3DREP 6../..XE, RE 29184-XE-B/04.16
9 Operation
9.1 General information
WARNING
Explosion hazard caused by overheating!
Loss of explosion protection due to overheating.
In case of valves with two solenoids, the sum of both solenoid currents may be
max. 1.03A at any time.
In case of bank assembly, if only one of the solenoids is energized at a time,
andduring individual operation, the maximum ambient temperature may not
exceed 60°C.
In case of bank assembly of valves, only one valve may be operated at a time.
The limit values for pulse voltage and clock frequency during operation of valve
solenoids with clocked voltage have to be observed. See "Data sheet 29184-XE".
CAUTION
Loud noise!
In case of an unfavorable disposition of valves, resonance or fluid noises,
e.g.whistling, may result. In continuous operation, these noises may cause
hearingdamage in persons or damage at the valves.
In this case, contact a service engineer.
Only use the valve within the performance range provided in "Data sheet 29184-XE".
The machine or system manufacturer is responsible for the correct project planning
of the hydraulic system and its control.
Changing the settings at the valve is not admissible.
For information on the operation, please refer to the operating instructions for
the hydraulic system into which the valve is installed.
If errors occur, refer to chapter 14 "Troubleshooting".