Product information 19/48
RE29583-XL-B/09.20, 4WS2EM 10...XL..., BoschRexrothAG
5.1.2 Explosion protection marking
The user/machine end-user has to classify potentially explosive atmospheres
according to EU directive1999/92/EC into zones. The table below lists zones with
device groups and categories.
The valve may only be used in the areas and zones which correspond to the device
group and category. During use, also observe the other information on explosion
protection in "Datasheet29583-XL".
Table 6: Device groups and categories
Zones, device groups
and categories
Device group
according to
2014/34/EU
Category
accordingto
2014/34/EU
Area of application, properties (excerpt from the directives) Usable in zone
accordingto
1999/92/EC
I M1 Firedamp areas (=device groupI), i.e. underground parts of mines and their
overground systems. In case of an explosive atmosphere, further operation
is possible.
Very high safety level.
-
I M2 Firedamp areas (=device groupI), i.e. underground parts of mines and their
overground systems. In case of an explosive atmosphere, it must be possible to
deactivate the device.
High safety level.
-
II 1G Potentially explosive atmospheres in which explosive gases, mists or vapors
(=device groupII) occur permanently or for along time or frequently.
Corresponds to zone 0 accordingto Directive1999/92/EC.
Very high safety level.
0, 1, 2
II 2G Potentially explosive atmospheres in which explosive gases, mists or vapors
(=device groupII) are occasionally present.
Corresponds to zone 1 accordingto Directive1999/92/EC.
High safety level.
1, 2
II 3G Potentially explosive atmospheres in which explosive gases, mists or vapors
(=device groupII) do not normally occur or only rarely or for ashort time.
Corresponds to zone 2 accordingto Directive1999/92/EC.
Normal safety level.
2
II 1D Potentially explosive atmospheres in which explosive dust/air mixtures
(=device groupII) are continually, long-term or often present.
Corresponds to zone 20 accordingto Directive1999/92/EC.
Very high safety level.
20, 21, 22
II 2D Potentially explosive atmospheres in which explosive dust/air mixtures
(=device groupII) are occasionally present.
Corresponds to zone 21 accordingto Directive1999/92/EC.
High safety level.
21, 22
II 3D Potentially explosive atmospheres in which an explosive atmosphere due to stirred
dust (=device groupII) is normally not present or occurs only rarely or only for a
short period of time.
Corresponds to zone 22 accordingto Directive1999/92/EC.
Normal safety level.