Commissioning 33/48
RE29583-XL-B/09.20, 4WS2EM 10...XL..., BoschRexrothAG
8 Commissioning
WARNING
Faulty installation!
If the valve is not correctly mounted, persons might be injured or the product or
system could be damaged when commissioning the valve.
Only commission your system when all hydraulic connections and the valve
have been completely and properly mounted according to the specifications.
Look out for defective sealing points and exchange defective seal rings
immediately.
Wear personal protective equipment during the initial commissioning.
Inadmissibly high operating pressure!
In hydraulic applications with different area ratios, the hydraulic pressure is
fortified and may - in case of incorrect design - lead to an exceedance of the
maximum admissible operating pressure. Thus, the valve may burst or the closing
elements may be ejected and cause personal injury.
Before commissioning the hydraulic system, ensure that the maximum
admissible pressure of the hydraulic valve in the system is not exceeded by
any means.
Ensure that, in your system, the maximum admissible operating pressure is
secured by means of apressure limitation element.
Damage to persons and property!
The commissioning of the valve requires basic hydraulic and electrical knowledge.
Only qualified personnel (seesection 2.4 "Qualification of personnel")
is authorized to commission the valve.
Proceed as described in the following sections to commission the valve:
Have the electrical connections checked for proper condition by or under the
guidance and supervision of aspecialized electrician before the initial
commissioning or any re-commissioning.
If possible, only check the hydraulic functions in acontrolled way and at low
pressure.
For the control and functional test, special test devices are available. Refer to
chapter7.6 "Required accessories".
Ensure that no hydraulic fluid leaks on the valve or on the connections
during operation.
Checking electrical
connections
Performing afunctional
test
Performing aleak test