F 037 300 069 (2013.05.21)
40
Error CIMS -> MASTER
Byte Contents Value
0x01 - Illegal Function - If the Function Code is not supported.
0x02 - Illegal Data Address - If Service ID not supported.
3 CRC XXh
4 XXh
C.4 READ IDENTIFICATION DATA
To read out the Identification Data the Encapsulated Interface Transport 2Bh/0Eh is implemented
as described in the MODBUS Application Protocol Specification V1.1b. The CIMS Sensor supports
currently only the Individual Access (0x04). The Stream Access (0x01 to 0x03) is not supported
and results in an Error Message. In addition to the Basic Identification Data the CIMS Sensor also
supports the Extended Identification Data. The Regular Identification Data are not supported and
results in an Exception Code.
C.4.1 POSSIBLE ERROR MESSAGES
Error CIMS -> MASTER
Byte Contents Value
0 Slave Address A2h
1 Error Function Code (Function Code + 80h) ABh
2
Exception Code
0x04 - Slave Device Failure - If the syntax of the request is wrong.
XXh
3 CRC XXh
4 XXh
C.4.2 READ VENDOR NAME (00H)
Read out the Vendor Name.
Request MASTER -> CIMS
Byte Contents Value
0 Slave Address A2h
1 Function Code - Encapsulated Interface Transport 2Bh
2 MEI Type - Read Device Identification 0Eh
3 Read Device ID code - Specific Identification Object (Individual Access) 04h
4 Object ID - Vendor Name 00h
5 CRC XXh
6 XXh
Response CIMS -> MASTER
Byte Contents Value
0 Slave Address A2h
1 Function Code - Encapsulated Interface Transport 2Bh
2 MEI Type - Read Device Identification 0Eh
3 Conformity Level - Extended Identification (Individual Access) 83h
4 More Follows 00h
5 Next Object Id 00h
6 Number of Objects 01h
7 Object ID - Vendor Name 00h
8 Object Length LLh
9 Payload XXh