F 037 300 069 (2013.05.21)
44
Response CIMS -> MASTER
Byte Contents Value
8 Object Length LLh
9
Payload
Coding: ASCII string
Length: Variable, the byte 8 contains the used length LL (maximum length: 16 byte).
Format: ‘F 037 XXX XXX-XX’
Example: 'F 037 B00 001-01'
XXh
... ...
8+LL XXh
9+LL CRC XXh
10+LL XXh
C.4.8 READ BOOTLOADER IDENTIFICATION NUMBER (B0H)
Read out the Bootloader Identification Number.
Request MASTER -> CIMS
Byte Contents Value
0 Slave Address A2h
1 Function Code - Encapsulated Interface Transport 2Bh
2 MEI Type - Read Device Identification 0Eh
3 Read Device ID code - Specific Identification Object (Individual Access) 04h
4 Object ID - Bootloader Identification Number B0h
5 CRC XXh
6 XXh
Response CIMS -> MASTER
Byte Contents Value
0 Slave Address A2h
1 Function Code - Encapsulated Interface Transport 2Bh
2 MEI Type - Read Device Identification 0Eh
3 Conformity Level - Extended Identification (Individual Access) 83h
4 More Follows 00h
5 Next Object Id 00h
6 Number of Objects 01h
7 Object ID - Bootloader Identification Number B0h
8 Object Length 0Dh
9
Payload
Coding: ASCII string
Length: 13 Byte
Example: 'F 037 SW0 003'
XXh
... ...
21 XXh
22 CRC XXh
23 XXh
C.4.9 READ BOOTLOADER VERSION (B1H)
Read out the Bootloader Version.
Request MASTER -> CIMS
Byte Contents Value
0 Slave Address A2h
1 Function Code - Encapsulated Interface Transport 2Bh
2 MEI Type - Read Device Identification 0Eh
3 Read Device ID code - Specific Identification Object (Individual Access) 04h