Rexroth Diax 04 HDD and HDS Ratings and Dimensions 3-1
DOK-DIAX04-HDD+HDS*UL*-IB01-EN-P
3 Ratings and Dimensions
3.1 HDD02.2 and HDS02.2-W040N
Description Symbol Unit
HDD02.2-
W016N
-HD32
HDD02.2-
W040N
-HD32
HDS02.2-
W040N
listing according UL-standard (UL) UL 508 C
listing according CSA-standard (UL) Canadian National Standard(s) C22.2 No. 14-05
UL files (UL) E 134201
pollution degree (UL) Use in a pollution degree 2 environment
maximum ambient temperature with nominal
data (UL)
T
amax
°C 45
maximum ambient temperature with reduced
nominal data (UL)
T
amax_red
°C 55
Weight m kg 7 7 6,5
device height (UL)
1)
H mm 498
device depth (UL)
2)
T mm 308
device width (UL)
3)
Bmm 50
minimum distance on the top of the device
4)
d
top
mm 300
minimum distance on the bottom of the device
5)
d
bot
mm 100
rated control voltage input (UL)
6)
U
N3
V 26 ±2%
rated power consumption control voltage input
without holding brake, without control section
at U
N3
= DC 24 V (UL)
P
N3
W454520
short circuit current rating, SCCR,
symmetrical amperes (UL)
7)
I
SCCR
A rms 42000
rated input voltage, power (UL)
8)
V 530 … 670
maximum input current (UL)
9)
I
L_cont
A 8,7 25 37
field wiring material (UL)
10)
Use 60/75 °C copper wire only, use class 1 wire
only or equivalent
maximum output voltage (UL) U
out
V 500
output number of phases (UL) 3
maximum output current (UL) I
out_max
A 8,5 15 20
maximum output frequency (UL) f
out
Hz 1000
power dissipation at continuous current I
out_cont
and continuous DC bus power P
DC_cont
respectively (UL)
11)
P
Diss_cont
W
75
per axis
110
per axis
125
1) 2) 3)
housing dimension; see related dimension sheet also
4) 5)
see fig. "Air intake and air outlet of drive controller"
6)
observe supply voltage for motor holding brakes
7)
Suitable for use on a circuit capable of delivering not more than this
SCCR value, 600 V AC or less. The drive series shall be used with
listed AC input line fuses or listed circuit breakers specified in this
documentation.
8)
HDS, HDD, HZB, HZK: DC bus L+, L-; HVE/HVR: mains input U, V, W
9)
at P
DC_cont
10)
tightening torque: see project planning manual, electrical terminals
11)
plus dissipation of braking resistor