EasyManua.ls Logo

Bosch Rexroth Diax 04 - Ratings and Dimensions; HDD;HDS Model Specifications

Bosch Rexroth Diax 04
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rexroth Diax 04 HDD and HDS Ratings and Dimensions 3-1
DOK-DIAX04-HDD+HDS*UL*-IB01-EN-P
3 Ratings and Dimensions
3.1 HDD02.2 and HDS02.2-W040N
Description Symbol Unit
HDD02.2-
W016N
-HD32
HDD02.2-
W040N
-HD32
HDS02.2-
W040N
listing according UL-standard (UL) UL 508 C
listing according CSA-standard (UL) Canadian National Standard(s) C22.2 No. 14-05
UL files (UL) E 134201
pollution degree (UL) Use in a pollution degree 2 environment
maximum ambient temperature with nominal
data (UL)
T
amax
°C 45
maximum ambient temperature with reduced
nominal data (UL)
T
amax_red
°C 55
Weight m kg 7 7 6,5
device height (UL)
1)
H mm 498
device depth (UL)
2)
T mm 308
device width (UL)
3)
Bmm 50
minimum distance on the top of the device
4)
d
top
mm 300
minimum distance on the bottom of the device
5)
d
bot
mm 100
rated control voltage input (UL)
6)
U
N3
V 26 ±2%
rated power consumption control voltage input
without holding brake, without control section
at U
N3
= DC 24 V (UL)
P
N3
W454520
short circuit current rating, SCCR,
symmetrical amperes (UL)
7)
I
SCCR
A rms 42000
rated input voltage, power (UL)
8)
V 530 … 670
maximum input current (UL)
9)
I
L_cont
A 8,7 25 37
field wiring material (UL)
10)
Use 60/75 °C copper wire only, use class 1 wire
only or equivalent
maximum output voltage (UL) U
out
V 500
output number of phases (UL) 3
maximum output current (UL) I
out_max
A 8,5 15 20
maximum output frequency (UL) f
out
Hz 1000
power dissipation at continuous current I
out_cont
and continuous DC bus power P
DC_cont
respectively (UL)
11)
P
Diss_cont
W
75
per axis
110
per axis
125
1) 2) 3)
housing dimension; see related dimension sheet also
4) 5)
see fig. "Air intake and air outlet of drive controller"
6)
observe supply voltage for motor holding brakes
7)
Suitable for use on a circuit capable of delivering not more than this
SCCR value, 600 V AC or less. The drive series shall be used with
listed AC input line fuses or listed circuit breakers specified in this
documentation.
8)
HDS, HDD, HZB, HZK: DC bus L+, L-; HVE/HVR: mains input U, V, W
9)
at P
DC_cont
10)
tightening torque: see project planning manual, electrical terminals
11)
plus dissipation of braking resistor
Abb. 3-1: UL ratings and dimensions