7 Connections and Interfaces......................................................................................... 23
7.1 Overview about the Connections on the Front Panel........................................................................... 23
7.2 Power Supply........................................................................................................................................ 24
7.2.1 External Supply Voltages.................................................................................................................. 24
General Information........................................................................................................................ 24
24 V Supply Voltage ULS............................................................................................................... 25
+24-V Supply of Main Circuit UM................................................................................................... 25
+24 V Supply of Segment Circuit US.............................................................................................. 26
7.2.2 Internally Generated Voltages........................................................................................................... 27
+7.5 V Inline Supply UL.................................................................................................................. 27
+24 V Analog Supply (UANA)......................................................................................................... 28
7.3 Digital Inputs and Outputs.................................................................................................................... 28
7.3.1 Address Assignment of Inputs and Outputs...................................................................................... 28
7.3.2 Digital On-board Inputs...................................................................................................................... 29
7.3.3 Digital Outputs................................................................................................................................... 30
7.4 Interfaces.............................................................................................................................................. 33
7.4.1 Ethernet Interface.............................................................................................................................. 33
7.4.2 Interface for the Compact Flash Card............................................................................................... 33
7.5 Inline Bus.............................................................................................................................................. 34
8 Installation and Maintenance....................................................................................... 35
8.1 Mechanical Installation of the IndraControl L10.................................................................................... 35
8.1.1 General Information........................................................................................................................... 35
8.1.2 Mounting the IndraControl L10.......................................................................................................... 35
8.1.3 Dismounting the IndraControl L10..................................................................................................... 35
8.2 Electric Installation................................................................................................................................ 36
8.2.1 General Information........................................................................................................................... 36
8.2.2 External Power ................................................................................................................................. 36
8.2.3 24 V Power Supply............................................................................................................................ 37
Setup without Electrical Isolation.................................................................................................... 37
Setup with Electrical Isolation ........................................................................................................ 37
Reference Conductor Connected to the Protective Conductor...................................................... 38
Reference Conductor Not Connected to the Protective Conductor................................................ 39
Programming Device and Ground Connection............................................................................... 40
Dimensioning the Voltage Supply................................................................................................... 40
8.2.4 Main Switches and Fuses.................................................................................................................. 40
Main Switches ............................................................................................................................... 40
Fuses.............................................................................................................................................. 41
8.2.5 Ground Connection........................................................................................................................... 41
8.2.6 Shield System ................................................................................................................................... 42
General Information........................................................................................................................ 42
8.2.7 Connecting Lines to Tension Spring Connection Points................................................................... 42
General Information........................................................................................................................ 42
Connecting Unshielded Lines......................................................................................................... 43
8.3 Maintenance......................................................................................................................................... 43