R911310381 / 02 | Rexroth IndraControl VCP 20 Electric Drives and Controls | Bosch Rexroth AG 7-3
Interfaces
7.1.1.3 Diagnostics
Ethernet diagnostics LEDs are located at the side of the operating
device.
Fig. 7-3: Position of the Ethernet diagnostics LEDs
7.1.2 USB (X9, X10)
Two host interfaces are available on the operating device.
7.1.2.1 Cable
No. Color State Designation Function
1 Green ON XMT Sending Ethernet Data Tele-
gram
2Yel-
low
ON RCV Receiving Ethernet Data
Telegram
Fig. 7-4: Function of the Ethernet diagnostics LEDs
Using input devices not suitable for industrial use (e.g. keyboard,
mouse) may decrease safety of operation. This includes input devices
intended for home and office use.
For the specification of a suitable cable, please refer to the „Universal
Serial Bus Specification Rev. 2.0“.
The maximum cable length for the cable used is 2.5 m (8.202 feet).